CANON    Digital Galvano Scanner System
 
KP-1SM Series + GC-251 
Users Manual 1.00 
 
 
 
  
45
5.3. 
Digital Input-Output Function 
The controller has a digital input-output function for checking the status of the controller. 
 
Pin 
No. 
I/O Signal 
Description  Logic 
Explanation 
A1 
Output 
Axis 1 Error 1 (Priority high) 
1: 
Error 
If an error occurs, the 
corresponding error signal is 
output. 
According to the priority of the 
error, Error 1 or 2 is output. 
See 9-2, “Errors.” 
B1 
Output 
Axis 1 Error 2 (Priority low) 
1: Error 
B2 
Output 
Axis 2 Error 1 (Priority high) 
1: Error 
A3 
Output 
Axis 2 Error 2 (Priority low) 
1: Error 
A2 
Output 
Axis 1 servo interrupt period 
Edge 
These are output at a servo 
interrupt timing in the 
controller. 
B3 
Output 
Axis 2 servo interrupt period 
Edge 
 
In addition, the following, digital I/O is prepared as an operation setting of the controller. 
 
Pin 
NO. 
I/O Signal 
Description 
Logic 
Explanation 
A5 
Input  External Sampling Signal 
↑:
INT 
generation 
When external signal is used for 
servo sampling clock.   
(Do not use it usually.) 
B5 Input 
External 
Trigger 
Signal 
High:ON 
See 6-2, “Operation that 
synchronizes with external 
trigger Signal input(raster scan) 
 
A6 
Input  Activation mode switching 
 
See 6-1, “Setting Controller 
Activation Mode”