CANON    Digital Galvano Scanner System
 
KP-1SM Series + GC-251 
Users Manual 1.00 
 
 
 
  
46
6. Other - Operation Setting 
 
6.1. Setting 
Controller Activation Mode 
Clock selection 
With the default settings at shipping, a parameter is set to activate the controller with the internal clock. 
When assembling the device, however, the mode can be switched for activation with an external clock 
(high-speed serial communication). For this switching, the following parameter is set: 
 
Parameter ID 
Data 
64 
Bit 1      0: Internal clock 
       1: High-speed serial communication 
 
              P64 = 1: Activation with internal clock 
              P64 = 3: Activation by high-speed serial communication 
 
(Bit 0 of P64 is used to enable or disable encoder correction when homing to the origin; it is usually set 
to 1. For details, see 8-2, “Parameter Details.”) 
 
Activation mode 
Power-on usually executes the following automatically: 
      ・Reading parameters from EEPROM 
      ・Starting homing and servo control 
If there is a problem with the parameters read from EEPROM or if oscillation occurs when homing and 
servo control are executed automatically, the power-on activation mode can be changed. 
 
For this switching, the switches (SW1 and SW2) on the controller board and the logic of the digital I/O 
terminal (A6) are combined.