[PROJECTOR SETUP] menu
ENGLISH - 103
Settings
10)  Press ▲▼ to select [CALIBRATION 
TIME].
11)  Press the <ENTER> button.
12)  Enter the time and press the <ENTER> 
button
z
Measure brightness at a specified time. 
Dynamic iris is fixed to open during 
measurement.
13)  Press ▲▼ to select [CALIBRATION 
MESSAGE].
14)  Press ◀▶ to switch [CALIBRATION 
MESSAGE].
z
The setting will change as follows each time 
you press the button.
[ON]
[OFF]
[ON]
Displays a message during 
calibration.
[OFF]
Does not display a message during 
calibration.
15)  Press ▲▼ to select [APPLY].
16)  Press the <ENTER> button.
z
The set [MODE] and [LINK] are enabled, and 
LAMP RELAY screen alert is displayed when 
the [LAMP RELAY] setting is [OFF]. When 
[CALIBRATION MESSAGE] is set to [ON], a 
calibration running message is displayed which 
will automatically disappear 30 seconds after 
calibration completes.
z
If the [MODE] in [BRIGHTNESS CONTROL 
SETUP]  is not [OFF] when the <ENTER> 
button is pressed, the lamp brightness at that 
time is recorded as the standard brightness.
z
If the <ENTER> button is pressed when [LINK] 
is [GROUP A] to [GROUP D], the group name 
is displayed on the projector screen set as the 
same group.
/,1.
*5283$
Note
 
z
When setting the [MODE] in [BRIGHTNESS 
CONTROL SETUP] to [AUTO] or [PC], [APPLY] 
luminance control after the shutter is open for at 
least two minutes.
 
z
If the shutter is closed within approx. 10 minutes 
from the time that the lamp turns on when operating 
with the [MODE] in [BRIGHTNESS CONTROL 
SETUP] set to [AUTO] or [PC], brightness may be 
corrected approx. two minutes after the shutter 
opens because brightness could not be measured.
 
z
When operating with the [MODE] in [BRIGHTNESS 
CONTROL SETUP] set to [AUTO] or [PC], lamp 
brightness is automatically measured eight minutes 
after a lamp is turned on, and corrected to the same 
value as the screen brightness and the standard 
brightness at the time of [APPLY]. Lamp brightness 
cannot be measured during the eight minutes after 
it is turned on because it is not steady.
 
z
When [LAMP SELECT] is 2 lit or higher and the 
[MODE] in [BRIGHTNESS CONTROL SETUP] is 
operating in [AUTO] and a light fails to turn on or 
LAMP RELAY is performed, brightness is corrected 
one minute later whenever possible.
 
z
When operating with [MODE] in [BRIGHTNESS 
CONTROL SETUP] set to [AUTO], and [LINK] is 
[OFF], brightness correction is performed until 
correction exceeds the maximum correction 
amount.
 
z
In certain projector environments, dust may 
accumulate on the lens or screen or inside the 
projector and increase variation in brightness.
 
z
Adjust luminance control again when lamp 
degradation causes increased variation in 
brightness or a lamp is replaced.
 
z
For continued use longer than 24 hours, set 
the [BRIGHTNESS CONTROL SETUP] to 
[CALIBRATION TIME], or set [LAMP RELAY] 
(
 page 101). Correction is not automatically 
executed when not set.
 
z
Luminance control and iris operate simultaneously, 
but the iris does not operate when fully open while 
a brightness measurement is performed.
 
z
The setting of [CALIBRATION TIME] applies at the 
time when the time is entered.
 
z
The setting of [CALIBRATION MESSAGE] applies 
at the time when the item is switched with ◀▶ .