Raypak 1334001 用户手册

下载
页码 52
9
NOTE: The heater shall be installed in a space large in comparison to the size of the heater. Large space is
defined as having a volume at least sixteen (16) times the total volume of the heater.
MODELS 0182-0400 and 0181-0401
MODEL 0133
Specifications and Dimensions
NOTE:
Ratings are shown for elevations up to 2,000 feet.  For elevations
over 2,000 feet, reduce ratings 4% for each 1,000 feet above sea
level.
NOTE:
Ratings are shown for elevations up to 2,000
feet.  For elevations over 2,000 feet, reduce
ratings 4% for each 1,000 feet above sea level.
Bold type indicates Low NOx models.
Model
Number
Indoor
Outdoor
Input MBH
Recovery
GPH*
Recovery
GPH*
WH-0133
136.0
135
132
* Recovery based on manufacturer’s rating.
Model Number
Indoor
Dimensions (in inches)
Input
MBH
Recovery
GPH*
Width
A
Height
C
J
Flue
Diameter
K
WH-0182/0181
181.0
180
18-1/4
62-5/8
12-1/16
6
WH-0206/0261
264.0
262
22-3/8
62-7/8
11-1/8
7
WH-0330/0331
334.0
332
25-3/4
63-3/4
10-3/4
8
WH-0400/0401
399.0
397
29-1/4
65-3/8
12-1/2
9
* Recovery based on manufacturer’s rating.