Rinnai R98LSI 用户手册

下载
页码 44
 
30 
VA Series Indoor LS Manual 
24"
V
  Additional Clearances  - Vent Terminal 
                       
Local codes supersede these clearances. 
• 
Avoid termination locations near a dryer vent. 
• 
Avoid termination locations near commercial cooking exhaust. 
• 
For VA3237 air intake position, follow the ANS Z21.10.3 ● CSA 4.3 requirements on the previous page. 
60"
V
V
(1.52 m) between 
Rinnai terminals 
at different levels 
12"
12"
36"
INSIDE
CORNER
V
V
(0.91 m) to ventilated 
or unventilated soffit 
or eve vent; or to a 
deck or porch 
(0.30 m ) to an 
inside corner 
(0.30 m) between 
Rinnai terminals at 
same level 
(0.61 m) to wall or parapet 
 
(0.30 m) between 
Rinnai terminals at 
same level 
12"
V
V
(1.52 m) vertically 
between Rinnai terminals 
V
60"
V
Vent terminal (represents concentric vent terminal or VA3237 exhaust only vent terminal)