  Gas Piping   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
General Instructions 
•  A manual gas control valve must be placed in the 
gas supply line to the Rinnai water heater.  A union 
can be used on the connection above the shut off 
valve for the future servicing or disconnection of the 
unit. 
•  Check the type of gas and the gas inlet pressure 
before connecting the Rinnai water heater.  If the 
Rinnai water heater is not of the gas type that the 
building is supplied with, DO NOT connect the water 
heater.  Contact the dealer for the proper unit to 
match the gas type. 
•  Check the gas supply pressure immediately 
upstream at a location provided by the gas 
company.  Supplied gas pressure must be within the 
limits shown in the Specifications section. 
•  Before placing the appliance in operation all joints 
including the heater must be checked for gas 
tightness by means of leak detector solution, soap 
and water, or an equivalent nonflammable solution, 
as applicable.  (Since some leak test solutions, 
including soap and water, may cause corrosion or 
stress cracking, the piping shall be rinsed with water 
after testing, unless it has been determined that the 
leak test solution is non-corrosive.) 
•  Always use approved connectors to connect the unit 
to the gas line.  Always purge the gas line of any 
debris before connection to the water heater. 
•  The gas supply line shall be gas tight, sized, and so 
installed as to provide a supply of gas sufficient to 
meet the maximum demand of the heater and all 
other gas consuming appliances at the location 
without loss of pressure. 
•  Any compound used on the threaded joint of the gas 
piping shall be a type which resists the action of 
liquefied petroleum gas (propane / LPG). 
•  Refer to an approved pipe sizing chart if in doubt 
about the size of the gas line. 
  Electrical 
Connection 
     
 
 
 
 
 
 
 
 
 
 
 
 
The water heater requires 120 VAC, 60 Hz power from a properly grounded circuit. 
If using the 6 foot long power cord, plug it into a standard 3 prong 120 VAC, 60 Hz properly grounded wall outlet.   
The wiring diagram is located on the Technical Sheet attached to the inside of the front cover. 
The water heater must be electrically grounded in accordance with local codes, or in the absence of local codes 
with the National Electrical Code, ANSI/NFPA 70 and/or the CSA C22.1, Canadian Electrical Code
  Error Indication or Air Handler Control Switch (RL75i, and RL94i only)   
 
When using the Rinnai water heater with an Error Indication Switch, switch No. 4 in the bank of 8 switches should 
be in the off position.  This is the default position. 
To connect the water heater to the Rinnai Air Handler, the Control Switch is necessary to function as the electrical 
connection.  When the Control Switch is functioning as the electrical connection between the water heater and air 
handler, switch No. 4 in the bank of 8 switches should be in the on position. 
The Error Indication Switch and the Rinnai Air Handler Control Switch are optional products available from Rinnai.  
Installation instructions are included with these products.