Isolation Valves and Pressure Relief Valve (RL75i and RL94i) 
  Water 
Piping 
        
 
 
 
 
 
 
 
 
 
 
 
 
The isolation valves provide the ability to isolate the 
water heater from the structure’s plumbing and allow 
quick access to flush the heat exchanger.  Check with 
local codes to determine if a pressure and temperature 
relief valve is required.  The included valves meet 
American National Standard (ANSI Z21.10.3) / 
Canadian Standard (CSA 4.3)
 and are ANSI/NSF 61 
approved for potable water.  
 
Isolation Valves Installation Instructions: 
1.  Wrap the ends of the threaded water inlet & outlet 
on the tankless water heater,as well as the 
threaded end of the approved pressure relief valve  
with a minimum of 5 wraps of Teflon® tape. 
2.  Screw the pressure relief valve into the 3/4” 
threads opposite the wing handle on the HOT 
water service valve. (RED drain handle) (see 
Pressure Relief Valve Section for proper 
installation requirements) 
3.  Loosen the 3/4” union nut on the HOT water valve 
and connect to the HOT water outlet on the 
tankless water heater. If nut is removed, ensure 
that you realign the tailpiece accurately to the 
valve and that the black washer is positioned such 
that the raised metal edge of the valve is inside 
the washer. 
4.  Align the direction of the HOT water drain to the 
desired position. 
5.  Tighten the union assembly to the HOT water 
valve using approximately 15 foot lbs of torque. 
6.  Repeat steps 3-5 for the COLD water valve. 
(BLUE drain handle) for connection to the COLD 
water inlet on the tankless water heater. 
7.  Connect the INLET on the COLD water valve to 
the MAIN SOURCE of the water supply. 
8.  Connect the OUTLET on the HOT water valve to 
the HOT WATER plumbing system. 
9.  Ensure that both drain valve lever handles are in 
the closed position (perpendicular to the drain 
portion of the body). 
Isolation Valve (Cold) 
107000081 
Isolation Valve (Hot) 
107000083 
Pressure Relief Valve (PRV) 
107000085 
Pressure Relief Valve Installation Instructions: 
The PRV must be connected by the threaded 
connection opposite the wing handle on the hot water 
valve (designated by the RED drain handle) or the 
threaded connection on the side of the relocation 
fitting above the hot water valve. Installation must 
maintain a ¾” port size with no shut off valve or line 
restriction in-between the appliance and the PRV. The 
discharge line from the PRV should pitch downward 
and terminate 6” above drains where discharge will be 
clearly visible. The discharge end of the line shall be 
plain (unthreaded) and a minimum of ¾” in diameter. 
The discharge line material must be suitable for water 
at least 180º Fahrenheit and can be no more than 30 
feet in length and contain no more than 4 elbows or 
bends. No valve of any type may be installed in the 
discharge line of the pressure relief valve. 
Pressure Relief Valve Maintenance: 
For proper care of this approved pressure relief valve, 
it is recommended that the valve is manually operated 
once a year. In doing so, it will be necessary to 
take precautions with regard to the discharge of 
potentially scalding hot water under pressure. Ensure 
discharge has a place to flow. Contact with your body 
or other property may cause damage or harm. 
Please note that only the PRV in this package is 
certified by CSA International as an approved item. 
A  Pressure Relief Valve (PRV) 
B  PRV Discharge Outlet 
C  Hot Ball Valve Drain Handle 
D  Cold Ball Valve Drain Handle