Fisher D450003T012 用户手册

下载
页码 4
Type N201
3
 
Note  
If propane vapor pressure is used, atmospheric 
or room temperature below 8°F (-13,3°C) will 
limit supply pressure to below 30 psig (2,1 bar). 
To assure tight shutoff of the filler valve in this 
event, refer to the table below.
  
 
MINIMUM SUPPLY 
PRESSURE, PSIG (bar)
MAXIMUM RECOMMENDED 
PUMP DISCHARGE, PSIG (bar)
21 (1,4)
200 (13,8)
19 (1,3)
150 (10,3)
17 (1,2)
100 (6,9)
14 (0,97)
50 (3,4)
13 (0,90)
25 (1,7)
  5.  Attach the propane filling hose to one of the filler valve 
outlets.  Plug the other outlet.  The filling hose must be 
complete with a shutoff valve and suitable cylinder valve 
connection.  The filling hose and shutoff valve can be 
counterbalanced for easy handling if desired.
   
Operation   
  1.  Place cylinder on scale platform and connect filler hose.
  2.  Slide beam weight “H” to tare weight stamped on cylinder. 
  3.  Balance scales to compensate for the weight added by 
the filler hose and shutoff valve.  On some scales this can be 
done by means of a small weight near the beam pivot pin.  On 
others a suitable weight can be added to scale pan “F”. 
  4.  Add a 100 pounds (45,4 kg) weight (or the net weight 
desired) to scale pan “F”, and open the cylinder and hose 
valve for trial automatic filling operation.  
 
  5.  Proceed with filling operation until scale beam rises and 
contacts the trip valve stem.  The filler valve will close and 
the filling operation is complete.  This is indicated by the red 
button on top of the filler valve.  Close the hose shutoff valve 
and the cylinder valve.  
 
  6. Check weight of full cylinder on another scale.  Balance 
weight or the weight in scale pan “F” may have to be 
readjusted slightly until the correct cylinder weight is 
obtained.  Filling accuracy is largely dependent upon the 
condition of the scale used with Type N201.
  7. After the scales have been checked and adjusted, simply 
position the empty cylinder on the scale, connect the filling 
hose, slide beam weight “H” to the tare weight stamped on 
the cylinder, open the hose shutoff valve and the cylinder 
valve, and the N201 will fill the cylinder to the weight added 
on the scale pan.
 
Note  
When operating with high pump pressure, 
the filler valve may close off, then reopen 
for a short spurt and close off again.  This 
is due to the force of
 
the incoming liquid 
stream.  If the proper cylinder weight has 
been obtained before the additional spurt, 
the operator should immediately close the 
hose shutoff valve when the scale beam 
contacts the trip valve stem.  If the scales 
are balanced after the additional spurt, the 
operator should wait for this before closing 
the hose shutoff valve.
  
 
In Case of Trouble
  1.  If sticking of the main (upper) valve should occur, place a 
few drops of oil below the disc holder, Key No.5 in Figure 3. 
This can be done with an eye dropper or oil can through one 
of the outlet ports.  Refer to the disassembly instructions if this 
does not correct the situation.  
 
  2.  If the disc holder wears out quickly, check the outlet 
pressure of regulator no. 2.  Too high a regulator setting will 
cause the disc to fail.  Refer to step 4 under “Installation”.
  3.  If the trip valve stem “B” should stick, remove the lower 
trip valve body, and clean out all oil or grease.  Polish the 
seat in the trip valve body by rotating the eraser end of a 
pencil against the seat 10 or 12 times.
  
 
Disassembly
To check disc holder assembly, O-ring, and diaphragms 
proceed as follows (numbers in parenthesis refer to Key Nos. 
in Figure 3): 
  1.  Remove tubing connection from the angle adaptor in 
Type 67/683 (key 30).  
 
  2.  Mark the valve body (key 17), valve housing (key 2), 
and valve head (key 1) so that they can be aligned easily 
when reassembling.  
 
  3.  Remove cap screws (key 22). 
  4.  Separate the valve head (key 1), valve housing (key 2), and 
valve body (key 17).  Examine the upper and lower diaphragms 
(keys 10 and 32).  Replace if necessary. 
  5.  Remove orifice (key 3) and unscrew the disc holder 
assembly (key 5).  Examine and replace if necessary.  
  6.  Remove bushing (key 8) and take out the O-ring (key 7). 
Examine and replace if necessary.  Put Dow Corning #3 grease 
(or equivalent) on the O-ring.  
 
  7.  Make sure all parts are clean before reassembling. 
To reassemble
  
 
1.  Replace orifice (key 3) in valve head (key 1).  
 
  2.  Replace O-ring (key 7) and screw in bushing (key 8).
  3.  Replace disc holder assembly (key 5) and 
spring (key 21).  Screw the disc holder into the diaphragm 
head (key 9).  
  
  4.  Replace upper diaphragm (key 10) on the valve head 
(key 1).  Align the valve housing (key 2), spring (key 35), 
lower diaphragm assembly (key 32), and valve body (key 17) 
so that the cap screws (key 22) can be inserted.  
 
  5.  Connect tubing (key 39) to angle adaptor in  Type 67/683 
(key 30).