Display Name 
Definition 
Cause 
Action 
A15 
Memory error 2 
(EEP-ROM) 
EEP-ROM fault 
1. Faulty parts in the servo amplifier 
Checking method
Alarm (A15) occurs if power is 
switched on after disconnection 
of all cables but the control circuit 
power supply cables.
 
Change the servo amplifier. 
 
 
 
2. The number of write times to EEP-
ROM exceeded 100,000. 
 
 
 
 
3. The multi-revolution data, which is 
saved as a home position, read from 
EEP-ROM is abnormal. 
Execute a home position setting. 
A16 
Encoder error 1 
(At power on) 
1. Encoder connector (CN2) 
disconnected. 
Connect correctly. 
 
 
2. Encoder fault 
Change the servo motor. 
 
 
Communication 
error occurred 
between encoder 
and servo amplifier.  3. Encoder cable faulty 
(Wire breakage or shorted) 
Repair or change the cable. 
 
 
 
4. Encoder cable type (2-wire, 4-wire) 
selection was wrong in parameter 
setting. 
Correct the setting in the fourth digit of 
parameter No.PC22. 
A17 
Board error 
CPU/parts fault 
A19 
Memory error 3 
(Flash ROM) 
ROM memory fault 
Faulty parts in the servo amplifier 
Checking method
Alarm (A17 or A19) occurs if 
power is switched on after 
disconnection of all cables but the 
control circuit power supply cable.
 
Change the servo amplifier. 
A1A Motor 
combination 
error 
Wrong combination 
of servo amplifier 
and servo motor. 
Wrong combination of servo amplifier 
and servo motor connected. 
Use correct combination. 
1. Encoder connector (CN2) 
disconnected. 
Connect correctly. 
2. Encoder cable faulty 
(Wire breakage or shorted) 
Repair or change the cable. 
A20 
Encoder error 2  Communication 
error occurred 
between encoder 
and servo amplifier. 
3. Encoder fault 
Change the servo motor. 
Main circuit 
error 
1. Power input wires and servo motor 
power wires are in contact. 
Connect correctly. 
 
2. Sheathes of servo motor power 
cables deteriorated, resulting in 
ground fault. 
Change the cable. 
A24 
 
Ground fault 
occurred at the 
servo motor power 
(U,V and W phases) 
of the servo 
amplifier. 
3. Main circuit of servo amplifier failed. 
Checking method
Alarm (A24) occurs if the servo is
switched on after disconnecting
the U, V, W power cables from
the servo amplifier.
 
Change the servo amplifier. 
Absolute 
position erase 
Absolute position 
data in error 
1. Voltage drop in encoder 
(Battery disconnected.) 
After leaving the alarm occurring for a few 
minutes, switch power off, then on again. 
Always make home position setting again. 
 
 
2. Battery voltage low 
 
 
3. Battery cable or battery is faulty. 
Change the battery.  
Always make home position setting again. 
A25 
 Power 
was 
switched 
on for the first time 
in the absolute 
position detection 
system. 
4. Home position not set. 
After leaving the alarm occurring for a few 