Classification
crit
err
Fault Severity
Critical fault at the software level (stops task operation)
Fault involving a malfunction (operation interrupted)
Level
Error
Error
warning
notice
info
Fault not involving malfunction
Fault outside the system
Information on correct operation
Warning
Warning
Information
Message
Explanation
Response
A002 Protocol initialization failure (err)
%1 protocol not installed
Webview initialization failed.
The settings may be corrupted.
Correct the settings or restore the factory default settings.
%1
protocol type <LS/C|LS/D|LS/H|>
Message
Explanation
Response
A004 Fault in initial video input systems settings (warning)
initial video input %1 marked inactive
Because there was no input for the initial video input system, 
VB101 has switched to automatic detection mode. The settings may be corrupted.
Correct the settings or restore the factory default settings.
%1
Camera number (1-4)
Message
Explanation
Response
A005 Camera control channel assignment error (warning)
conflicting channel assignment for %1:%2
The same camera control port is assigned to multiple video input channels. 
The settings may be corrupted.
Correct the settings or restore the factory default settings.
%1
%2
Camera control port (CC1|CC2)
Cascade Number (1-4)
Message
Explanation
Response
A006 Camera control system initialization failure (err)
cannot open camera control port %1
The camera control port cannot be opened.
If rebooting does not recover this problem, there is a malfunction. Contact an authorized Canon service representative.
%1
Camera control port (CC1|CC2)
Log Messages
Log Messages for Applications
The Syslog log messages are classified into the following 5 categories. Classification details are dealt with
in the UNIX syslog and the levels are explained in Chapter 3 (
→P.58).
* The syslog facility is local7.