7.2 Power control 
1) The controller requests the monitor to control monitor power. 
 
Header 
SOH (01h): Start Of Header 
'0' (30h): Reserved 
Monitor ID: Specify the Monitor ID which you want to change a setting. 
Ex.) If Monitor ID is '1', specify 'A'. 
'0' (30h): Message sender is the controller. 
'A' (41h): Message type is "Command". 
'0'-'C (30h, 43h): Message length is 12 bytes. 
 
Message 
STX (02h): Start of Message 
'C'-'2'-'0'-'3'-'D'-'6' (43h, 32h, 30h, 33h, 44h, 36h): power control command 
'0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Power mode 
0001: ON 
0002, 0003: Do not set. 
0004: OFF (same as the power off by IR) 
ETX (03h): End of Message 
 
 
Check code 
BCC: Block Check Code 
      Refer to the section 4.5 
“Check code” for a BCC calculation. 
 
Delimiter 
CR (0Dh): End of packet 
 
2) The monitor replies a data for confirmation. 
 
Header 
SOH (01h): Start Of Header 
  '0' (30h): Reserved 
'0' (30h): Message receiver is the controller. 
Monitor ID: Indicate a replying Monitor ID. 
Ex.)  When this byte is set to 'A', the replying Monitor ID is '1'.  
'B' (42h): Message type is "Command reply". 
 
'N'-'N': Message length 
Note.) The maximum data length that can be written to the monitor at a time is 32bytes. 
Ex.) The byte data 20h is encoded as ASCII characters '2' and '0' (32h and 30h). 
 
Message 
STX (02h): Start of Message 
'0'-'0' (30h, 30h): Result code.  No error. 
'C'-'2
’,'0'-'3'-'D'-'6' (43h, 32h, 30h, 33h, 44h, 36h): power control reply command 
 
The monitor replies same as power control command to the controller. 
'0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Power mode 
0001: ON 
0002, 0003: Do not set. 
0004: OFF (same as the power off by IR) 
ETX (03h): End of Message 
 
Check code 
BCC: Block Check Code 
      Refer to the section 4.5 
“Check code” for a BCC calculation. 
Header 
Message 
Check code 
Delimiter 
SOH-'0'-Monitor ID-'0'-'A'-'0'-'C' 
STX-'C'-'2'-'0'-'3'-'D'-'6'- 
'0'-'0'-'0'-'1'-ETX 
BCC 
CR 
Header 
Message 
Check ode 
Delimiter 
SOH-'0'-'0'-Monitor 
ID-'B'-'0'-'E' 
STX-'0'-'0'-'C'-'2'-'0'-'3'-'D'-'6'- 
'0'-'0'-'0'-'1'-ETX 
BCC 
CR