8. Asset Data read and write 
MultiSync P402 /P462 /P552 /P702 /V422 /V462 /V551 /V651 /V322 /V652 /V552 /X461S /X551S /X401S 
/X463UN /X551UN /V463 /V423 have the area for to store user
’s asset data of up to 64bytes.   
8.1 Asset Data Read Request and reply
 
This command is used in order to read Asset Data.  
1) The controller requests the monitor to reply with Asset data. 
Header 
Message 
Check code 
Delimiter 
SOH-'0'-Monitor ID-'0'-'A'-'0'-'A' 
STX-'C'-'0'-'0'-'B'-'0'-'0'-'2'-'0'-ETX 
BCC 
CR 
 
Header 
SOH (01h): Start Of Header 
'0' (30h): Reserved 
Monitor ID: Specify the Monitor ID from which you want to get data. 
Ex.) If Monitor ID is '1', specify 'A'. 
'0' (30h): Message sender is the controller. 
'A' (41h): Message type is "Command". 
'0'-'A' (30h, 41h): Message length is 10 bytes. 
 
Message 
STX (02h): Start of Message 
'C'-'0'-'0'-'B'  (43h, 30h, 30h, 42h): Asset read request command. 
'0'-'0' (30h, 30h): Offset data from top of the Asset data.  
At first set 00h: Read data from the top of Asset data area.  
'2'-'0' (32h, 30h): Read out data length is 32bytes. 
Secondly set 20h: Read data from the 32bytes offset point in the Asset data area. 
Maximum readout length is 32bytes at a time.   
ETX (03h): End of Message 
 
Check code 
BCC: Block Check Code 
      Refer to the section 4.5 
“Check code” for a BCC calculation. 
 
Delimiter 
CR (0Dh): End of packet 
 
2) The monitor replies Asset data to the controller. 
Header 
Message 
Check code 
Delimiter 
SOH-'0'-'0'-Monitor ID-'B'-N-N 
STX-'C'-'1'-'0'-'B'- 
Data(0)-Data(1)---Data(N)-ETX 
BCC 
CR 
 
Header 
SOH (01h): Start of Header 
'0' (30h): Reserved 
'0' (30h): Message receiver is the controller. 
Monitor ID: Indicate a replying Monitor ID. 
Ex.)  When this byte is set to 'A', the replying Monitor ID is '1'.  
'B' (42h): Message type is "Command reply" 
N-N: Message length 
Ex.) The byte data 20h is encoded to ASCII characters '2' and '0' (32h and 30h). 
Note.) This length includes STX and ETX.
 
 
Message 
STX (02h): Start of Message 
'C'-'1'-'0'-'B'  (43h, 31h, 30h, 42h): Asset read reply command 
Data(0) 
– Data(N): Retuned Asset data 
ETX (03h): End of Message 
 
Check code 
BCC: Block Check Code 
      Refer to the section 4.5 
“Check code” for a BCC calculation.