Maintenance
Restoring from service position
1
Grip the front edge of the unit and loosen the lock, fold 
down and slide in the unit.
2
Replace the cutting height stay and the belt.
3
Tension the belt with the belt adjuster.
4
Fit the front cover.
Checking the blades
WARNING! Wear gloves to protect your hands when working 
with the blades.
To achieve the best mowing results it is important that the 
blades are undamaged and well-sharpened.
Check that the blades’ attachment screws are tight.
The blades should be balanced after sharpening.
Damaged blades should be replaced when hitting obstacles 
that result in a breakdown. Let the service centre assess 
whether the blade can be sharpened or must be replaced.
Removing the BioClip plug
To change a Combi unit from BioClip function to cutting unit 
with rear ejection, remove the BioClip plug located under the 
unit with three screws.
Combi 103, Combi 112
1
Put the unit in the service position, see Placing in the 
service position.
2
Remove the three screws holding the BioClip plug, and 
remove the plug.
3
Tip: Fit three full-thread screws M8x15 mm in the screw 
holes to protect the threads.
4
Replace the unit in normal position.
Fit the BioClip plug in the reverse order.
Combi 94
1
Put the unit in the service position, see Placing in the 
service position.
2
Loosen the knob and the bolts holding the BioClip plug 
and remove the plug.
IMPORTANT INFORMATION Replacing or sharpening the 
blades should be conducted by an authorised service 
workshop.