Generac 000 & 8 用户手册

下载
页码 56
 6 
Section 2 – Operation
Portable Generator System
2.2 HOURMETER
The Hourmeter tracks hours of operation for scheduled 
maintenance:
There will be a "CHG OIL" message every 100 hours. The message 
will flash one hour before and one hour after each 100 hour 
interval, again providing a two hour window to perform service.
This message will actually begin flashing at 99 hours and disable 
itself at 101 hours providing a two hour window to perform the 
service.
Every 200 hours the "SVC" icon on the lower left hand corner of 
the display will flash. The message will flash one hour before and 
one hour after each 200 hour interval providing a two hour window 
to perform service.
When the hour meter is in the Flash Alert mode, the maintenance 
message will always alternate with elapsed time in hours and 
tenths. The hours will flash four times, then alternate with the 
maintenance message four times until the meter resets itself.
100 hours - CHG OIL — Oil Change Interval (Every 100 hrs)
• 
200 hours - SVC — Air Filter Interval (Every 200 hrs)
• 
2.3  CORD SETS AND CONNECTION PLUGS
2.3.1  120 VAC, 20 AMP, DUPLEX RECEPTACLE
This is a 120 Volt outlet protected against overload by a 20 Amp 
push-to-reset circuit breaker (Figure 7). Use each socket to power 
120 Volt AC, single phase, 60 Hz electrical loads requiring up to a 
combined 2400 watts (2.4 kW) or 20 Amps of current. Use only 
high quality, well-insulated, 3-wire grounded cord sets rated for 
125 Volts at 20 Amps (or greater).
Keep extension cords as short as possible, preferably less than 
15 feet long, to prevent voltage drop and possible overheating of 
wires.
Figure 7 - 120 Volt AC, 20 Amp, Duplex Receptacle
2.3.2  120/240 VAC, 30 AMP RECEPTACLE
Use a NEMA L14-30 plug with this receptacle (rotate to lock/
unlock). Connect a suitable 4-wire grounded cord set to the plug 
and to the desired load. The cord set should be rated for 250 Volts 
AC at 30 Amps (or greater) (Figure 8).
Figure 8 - 120/240 VAC, 30 Amp Receptacle
Use this receptacle to operate 120 Volt AC, 60 Hz, single phase 
loads requiring up to 3600 watts (3.6 kW) of power at 30 Amps or 
240 Volt AC, 60 Hz, single phase loads requiring up to 7200 watts 
(7.2 kW) of power at 30 Amps. The outlet is protected by two 30 
Amp push-to-reset circuit breakers.
2.4  HOW TO USE THE GENERATOR
If there are any problems operating the generator, please call the 
generator helpline at 1-888-436-3722.
Using a generator indoors CAN KILL 
YOU IN MINUTES.
Generator exhaust contains carbon
monoxide.  This is a poison you
cannot see or smell.
Utiliser un générateur à l'intérieur PEUT
VOUS TUER EN QUELQUES MINUTES.
Les gaz d'échappement du générateur
contiennent du monoxyde de carbone.
C'est un gaz toxique invisible et inodore.
Si usa un generador en interiores,
MORIRÁ EN POCOS MINUTOS.
El escape del generador contiene
monóxido de carbono.  Es un veneno
que no tiene olor ni se puede ver.
NEVER use inside a home or garage, EVEN IF doors and windows are open. Only use OUTSIDE and far away from
windows, doors, and vents.
NE JAMAIS utiliser à l'intérieur d'une maison ou d'un garage, MÊME SI les portes et les fenêtres sont ouvertes. Utiliser
UNIQUEMENT à l'EXTÉRIEUR et loin des fenêtres, portes et ventilations.
NUNCA lo use dentro de una casa o garaje, AUN si las puertas y ventanas están abiertas. Sólo úselo EN EXTERIORES
y lejos de ventanas, puertas y ductos de ventilación.
2.4.1  GROUNDING THE GENERATOR
The National Electrical Code requires that the frame and 
external electrically conductive parts of this generator be 
properly connected to an approved earth ground (Figure 9)
Local electrical codes may also require proper grounding of the 
unit. For that purpose, connecting a No. 10 AWG (American Wire 
Gauge) stranded copper wire to the grounding lug and to an 
earth-driven copper or brass grounding rod (electrode) provides 
adequate protection against electrical shock. However, local codes 
may vary widely. Consult with a local electrician for grounding 
requirements in the area.