page 22 — ga6HB/ga6HeB 60 hz gENERATOR• OpERATiON ANd pARTs mANuAl — REv. #0 (03/13/14) 
oPeRaTion
This section is intended to assist the operator with the initial 
start-up of the portable generator. It is extremely important 
that this section be read carefully before attempting to use 
the generator in the field.
Before starting the Engine 
1.  Be sure to disconnect all electrical loads from the 
generator prior to starting the engine.
2. 
NEvER start the engine with the main circuit breaker 
in the 
ON position. Always place circuit breaker (Figure 12) 
in the 
OFF position before starting.
Figure 12. Main Circuit Breaker (OFF)
starting the Engine (Recoil start)
1.  Place the engine fuel valve lever (Figure 13) in the 
ON 
position.
Figure 13. Engine Fuel Valve Lever (ON)
2.  Place the choke lever (Figure 14) in the 
ClOsEd  
position if starting a cold engine.
 NOTICE
Both model generators are equipped with a GFCI 
sensing module. The purpose of this module is to 
sense a ground fault during operation of the generator 
and shut down the generator once the ground fault has 
been detected.
Multiquip recommends that the GFCI sensing module 
be tested before each use of the generator. Reference 
the maintenance section of this manual for the testing 
of the GFCI sensing module.
ON
OFF
Figure 14. Choke Lever
3.  Place the choke lever (Figure 14) in the 
OpeN position 
if starting a warm engine or the temperature is warm.
4.  Place the generator's operation switch (Figure 15) in 
the 
ON position.
Figure 15. Operation Switch (ON)
5.  If your generator is a recoil start only (no battery), grasp 
the starter grip (Figure 16) and slowly pull it out. The 
resistance becomes the hardest at a certain position, 
corresponding to the compression point. Pull the starter 
grip briskly and smoothly for starting.
Proceed to step 6 if your unit is an electric start model 
(battery installed).
Figure 16. Starter Grip
ON
OFF
GA-6HB
GA-6HEB
ON
 NOTICE
dO NOT pull the starter rope all the way to the end.
dO NOT release the starter rope after pulling. Allow it 
to rewind as soon as possible..