2.3.c Connecting DC Wires/PV Panels 
  
 
WARNING:  
Before proceeding with the DC wiring, completely cover the 
surface of all PV-arrays with dark material to avoid the production of electrical 
current
.  
 
 
WARNING:  
Make sure the polarity and the PV panel voltage between the + 
and the – cable connectors of the PV panels are correct.  Then connect the 
panels to the DC terminal block on the power distribution board.
 
 
The PV panel open circuit voltage should be at or below the listed voltages in Figure 9 
under all circumstances.  Each DC input to the DC terminal block must be less than the 
voltages listed in Figure 9. 
   
 
StarInverter 
Model
 
 
PV Panel Open Circuit 
Voltage 
 
DC Input to DC 
Terminal Block 
PVP1800 360V
DC 
360V
DC 
PVP2800 450V
DC 
450V
DC 
Figure 9:  PV open circuit voltages. 
 
To wire the DC inputs from the PV panels to the StarInverter (refer Figure 9): 
 
Note:  Each DC input connection must carry the same input voltage.  The StarInverter 
allows up to three connections for both the + and the – pole. 
 
1.  Calculate the maximum open circuit (no load) for each series panel connection.  
FOR ALL TEMPERATURE CONDITIONS, THE OPEN CIRCUIT VOLTAGE 
FOR EACH SERIES CONNECTION MUST TOTAL LESS THAN THE OPEN 
CIRCUIT VOLTAGE INDICATED IN FIGURE 9 FOR THE CORRESPONDING 
STARINVERTER MODEL. 
Review your panel’s data sheet for operating 
temperature ranges. 
 
2.  Keep track of the array positive and negative leads and mark them clearly. 
 
3.  Route the PV array leads through the far right opening in the StarInverter. 
 
4.  Connect each series positive DC lead to the positive terminals of the power 
distribution board. 
 
5.  Connect negative DC leads directly to the negative terminal on the power 
distribution board.   
 
6.  Connect the ground wire(s) to the ground lug.  