Revolutionary Cooling Systems PVP1800 用户手册

下载
页码 28
 
 
 
 
3.3.a Data Logging with the PVP Command Center 
 
Information obtained by the PVP Command Center is easily exported to an Excel 
spreadsheet where the following data is logged in one-minute increments: 
 
•  Date 
•  Time 
•  Utility RMS Voltage 
•  PV RMS Current 
•  PV DC In Voltage 
•  Power Out (AC Watts) 
•  Heat Sink Temperature 
 
To activate the Excel data logging capability (Refer to Figure 17): 
 
1)  From the Main Screen of the Command Center click on Setup>Toggle Data 
Logging Off/On to bring up the “Save Inverter Data As . . . “ window.  
2)  Name data logging file and save in desired location. 
3)  Open the data-logging file to display the specific inverter information outlined 
above.   
 
 
 
 
 
 
 
 
 
    
         
 
       
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 17:  Data Logging 
 
    
 
 
 
                                              
 
PV Powered LLC 
18 
18-28-405