Air-cooled 11 kW Generators
1.6   SPECIFICATIONS
1.6.1 GENERATOR
 
Model 04916-0
 Rated Max. Continuous Power Capacity (Watts*) 
10,000 NG/11,000 LP
 Rated Voltage 
120/240
 Rated Max. Continuous Load Current (Amps)
120 Volts** 
83.3 NG/91.7 LP
240 Volts 
41.7 NG/45.8 LP
 Main Line Circuit Breaker 
45 Amp
 Phase 
1
 Number of Rotor Poles 
2
 Rated AC Frequency 
60 Hz
 Power Factor 
1
 Recommended Air Filter 
Part # C8127
 Battery Requirement 
Group 26/26R 12 Volts and
 at -17.8° C (0° F) 
525 Cold-cranking Amperes Minimum
 Weight 
495 Pounds
 Output Sound Level @ 23 ft (7m) at full load 
62.2 db (A)
 Normal Operating Range 
-20°F (-28.8°C) to 104°F (40°C)
*  Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum power 
decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 6° C (10° F) above 16° C (60° F) ambient temperature.
**  Load current values shown for 120 volts are maximum TOTAL values for two separate circuits. The maximum current in each circuit must not exceed the value stated for 240 
volts.
1.6.2 ENGINE
 
Model 04916-0
 Type of Engine 
GT-990
 Number of Cylinders 
2
 Rated Horsepower 
30 @ 3,600 rpm
 Displacement 
992cc
 Cylinder Block 
Aluminum w/Cast Iron Sleeve
 Valve Arrangement 
Overhead Valves
 Ignition System 
Solid-state w/Magneto
 Recommended Spark Plug 
RC14YC
 Spark Plug Gap 
0.76 mm (0.030 inch)
 Compression Ratio 
9.5:1
 Starter 
12Vdc
 Oil Capacity Including Filter 
Approx. 1.7 Qts
 Recommended Oil Filter 
Part # 70185
 Recommended Air Filter 
Part # 0C8127
 Operating RPM 
2,700
‹
‹