Rename the NI 5650/5651/5652
MAX allows you to rename the NI 5650/5651/5652 hardware module. 
The MAX name is used in software to operate the NI 5650/5651/5652 
hardware resources. You do not have to change the module name from the 
default but doing so can make programming easier.
To rename the NI 5650/5651/5652 hardware modules, complete 
steps 1 through 4. If you do not wish to rename the modules, proceed to the 
Generate a Signal Using the NI 5650/5651/5652 RF Signal Generator Test 
Panel
 sectio
n.
1.
Right-click the NI 5650/5651/5652 module and select Rename from 
the shortcut menu.
2.
Enter the new name for the NI 5650/5651/5652 module.
Note
The device name must consist only of alphanumeric and underscore characters.
3.
Click OK.
4.
Verify that the new name for the module is displayed.
Generate a Signal Using the NI 5650/5651/5652 RF 
Signal Generator Test Panel
To verify your device configuration, use the NI-RFSG test panel in MAX 
to generate a simple signal using the NI 5650/5651/5652 RF signal 
generator hardware. Complete steps 1 through 6 to use the NI RF signal 
generator test panel.
1.
Right-click the NI PXI-5650/5651/5652 RF signal generator module 
and select Test Panels.
2.
In the Test Panels dialog box, specify a frequency and a power level for 
signal generation.
Caution
Running the test panel generates a signal from the RF OUTPUT front panel 
connector. Disconnect any equipment that can be damaged by the test signal prior to 
running the test panel.
3.
The test panel allows you to verify that the NI 5650/5651/5652 device 
is operating properly. Click Start to begin signal generation. During 
signal generation the ACTIVE LED on the NI 5650/5651/5652 
hardware module is illuminated.
Note
If the LED does not illuminate or if the NI RF signal generator test panel generates 
an error, refer to