Roland SPD-S 用户手册
72
Chapter 6 Using a CompactFlash Memory Card
BACKUP LOAD
Here's how to load backup data (SPD-S settings: patch, wave, setup) from a memory card.
Once you execute this operation, the loaded backup data will replace the settings currently within the SPD-S.
1.
Set the following parameter.
Press the PAGE buttons to change parameters and press [-]/[+] to change the value.
When Load was set to "1–4" in Step 1
2.
Press [>] so that “load, sure?” appears. Press [ENTER] to load the backup data selected in Load in Step
1.
While loading is in progress, “now processing..” is displayed. Afterwards, the SPD-S returns to the patch mode.
Do not power the unit off during execution.
When Load was set to "One Wave" in Step 1
2.
Set the following parameters as well.
Press the PAGE buttons to change parameters and press [-]/[+] to change the value.
3.
Press [>] so that “load wave, sure?” appears. Press [ENTER] to load the wave selected in Src in Step 1.
Do not power the unit off during execution.
4.
A “continue?” indication appears. If you press [ENTER], the SPD-S returns to the “Src” screen as in
Step 1, where you can continue your operation. If you press [EXIT], the SPD-S returns to wave mode.
Icon
Description
New (empty) backup data (will not load)
Previously saved backup data
Parameter
Value
Descriptions
Load
1–4,
One Wave
One Wave
1–4: To choose a set of backup data stored on a card.
One Wave: Selecting an individually stored wave in the backup data.
One Wave: Selecting an individually stored wave in the backup data.
Parameter
Value
Descriptions
Src
(Source)
(Source)
1001–1399,
2001–2399,
3001–3399,
4001–4399
2001–2399,
3001–3399,
4001–4399
Select the wave number(s) to be loaded from the backup data on a card. The left most digit
represents the backup data set number. The bottom three digits (001 to 399) represent the
wave number contained in the backup data set.
represents the backup data set number. The bottom three digits (001 to 399) represent the
wave number contained in the backup data set.
* Press [FUNC] and [-]/[+] to move to the beginning of the backup data set.
Dst
(Destina-
tion)
(Destina-
tion)
I
001–399,
C
001–500
Select the wave number to which the wave is loaded. The initial value is the top number of
the new (empty) waves.
the new (empty) waves.
I
001–399: To the internal memory
C
001–500: To the memory card
* By pressing [CARD], you can select the top number of the internal memory or of the
memory card.
* If you hold down [SHIFT] and press [FUNC], a new (empty) wave number is selected.
* While continuing to hold down [FUNC], the remaining capacity of the memory (“Re-
* While continuing to hold down [FUNC], the remaining capacity of the memory (“Re-
main”) is indicated.
SPDS_e.book 72 ページ 2004年4月19日 月曜日 午前9時58分