Troubleshooting
 
If you think there’s a problem, read this first.
 
Case
Cause/Remedy
 
The power doesn’t 
come on
 
Is the power cord connected and plugged in 
correctly? (p. 12)
 
The button doesn’t 
work
 
Is the panel locked? (p. 35)
Turn the power off, then back on.
 
No sound is heard
 
Is the volume level of the HP201 turned all the 
way down? (p. 14)
Are headphones plugged in? (p. 13)
Has a plug remained connected to the Phones 
jack?
Plugging headphones or other plugs into the 
headphone jack stops sounds from playing 
through the speakers.
Is Local Off selected? 
When Local Control is set to Off, no sound is 
produced by playing the keyboard. Set Local 
Control to “On” (p. 39).
Is V-LINK switched on?
While V-LINK is switched on, no sound is 
produced when you press any of the twelve 
keys at the left end of the keyboard (p. 35).
 
No sound is heard 
(when a MIDI 
instrument is 
connected)
 
Have all devices been switched on?
Are the MIDI cables connected correctly?
Does the MIDI channel match the connected 
instrument? (p. 38)
 
Sounds are heard 
twice (doubled) 
when the keyboard 
is played
 
When the HP201 is connected to an external 
sequencer, set it to the Local OFF mode 
(p. 39). 
Alternatively, the sequencer could be set so its 
MIDI Thru feature is OFF.
 
Tone doesn’t change
 
Is the panel locked? (p. 35)
Turn the power off, then back on.
 
Not all played notes 
are sounded
 
The maximum number of notes that the 
HP201 can play simultaneously is 128. 
Frequent use of the damper pedal when 
playing along with a song may result in 
performance data with too many notes, 
causing some notes to drop out.
 
The tuning or pitch of 
the keyboard or 
song is off
 
Is the setting for the “Master Tuning” correct? 
(p. 32)
 
Depressing a pedal 
has no effect, or the 
pedal effect doesn’t 
stop
 
Is the pedal connected correctly? 
Make sure the pedal cord is securely 
connected to the pedal jack on the bottom of 
the unit, at the rear (p. 12).
 
The pedal rattles
 
Adjust the adjuster underneath the pedal so 
that the adjuster presses firmly against the 
floor surface (p. 14).
 
In the upper range, 
the sound changes 
abruptly beyond a 
certain key
 
On an acoustic piano, notes in the upper one 
and a half octaves of the keyboard continue 
to sound until they decay naturally, regardless 
of the damper pedal. There is a difference in 
the timbre as well. Roland pianos faithfully 
simulate such characteristics of the acoustic 
piano. On the HP201, the range that is 
unaffected by the damper pedal will change 
depending on the Transpose setting.
 
A High-pitched 
whine is produced
 
When listening through headphones: 
Some of the more flamboyant and 
effervescent piano tones feature an ample 
high-end component, which may make 
the sound appear to have metallic 
reverberation added. Since this 
reverberation becomes particularly 
audible when supplemented by heavy 
reverb, you may be able to diminish the 
problem by reducing the amount of 
reverb applied to the sound.
When listening through speakers: 
Here, a different cause (such as 
resonance produced by the HP201) 
would be suspect. Consult your Roland 
dealer or nearest Roland Service Center.
 
The bass range 
sounds odd, or there 
is a vibrating 
resonance
 
When listening through speakers: 
Playing at loud volumes may cause 
instruments near the HP201 to resonate.
Resonation can also occur with 
fluorescent light tubes, glass doors, and 
other objects. In particular, this problem 
occurs more easily when the bass 
component is increased, and when the 
sound is played at higher volumes. Use 
the following measures to suppress such 
resonance. 
• Place speakers so they are 10–15 cm 
from walls and other surfaces. 
• Reduce the volume. 
• Move the speakers away from any 
resonating objects. 
When listening through headphones: 
Here, a different cause would be suspect. 
Consult your Roland dealer or nearest 
Roland Service Center.
 
The volume level of 
the instrument 
connected to Input 
jacks is too low
 
Could you be using a connection cable that 
contains a resistor? 
Use a connection cable that does not contain 