10
USING THE BUILT-IN BATTERY TESTER
OVERVIEW
This battery charger has a built-in battery 
tester that displays either an accurate 
battery voltage or an estimate of the 
battery’s relative charge based on the 
battery voltage and the Battery Council 
International scale.
TESTING SEQUENCE
There are four basic steps required to 
use the SC-6500A as a battery tester.
1.  Connect the charger battery clamps to 
the battery. Be sure to follow all of the 
precautions listed under “OPERATING 
INSTRUCTIONS”. 
2.  Connect the charger power cord to a 120V 
AC 2-prong wall outlet. Again, be sure to 
follow all of the precautions listed under 
“OPERATING INSTRUCTIONS”.
3.  If  necessary,  press  the  BATTERY 
TYPE  button  until  the  correct  type  is 
indicated.
4.  Read the voltage on the digital display 
or press the DIGITAL DISPLAY button 
to  set  the  tester  to  BATTERY  %  and 
read the battery percent.
TESTER AND CHARGER
When first turned on, the SC-6500A oper-
ates only as a tester, not as a charger. To 
continue to use it as only a tester, avoid 
pressing the CHARGE START switch 
button. Selecting a charge rate activates 
the battery charger and deactivates the 
tester. Pressing the CHARGE START but-
ton when the ENGINE START LED is lit 
(except during the 180 second cool down) 
will shut off the charger and activate the 
tester.
POWER-UP IDLE TIME LIMIT
If no switch button is pressed within 
15 minutes after the SC-6500A is first 
powered up, it will automatically switch 
from tester to charger, if a battery is 
connected. In that case, the charger will 
be set for the small battery rate and 12V 
REGULAR battery type.
TESTER WITHOUT TIME LIMIT
If either the DIGITAL DISPLAY or BAT-
TERY TYPE button is pressed within the 
first 15 minutes after the SC-6500A is 
powered up, it will remain a tester (not 
a charger) indefinitely, unless a charge 
rate is selected.
TESTING AFTER CHARGING
After the SC-6500A has been changed 
from tester to charger (by selecting a 
charge rate), it remains a charger. To 
change the SC-6500A back to a tester, 
press the CHARGE START button until 
all charge rate LEDs are off.
TESTER STATUS LEDs
When the SC-6500A is operating as 
a battery tester, the status LEDs light 
under the following conditions:
•  The CHARGED (green) LED will light if 
a charged battery is tested. 
•  The CHARGING (yellow) LED does not 
light in the battery test mode.
•  The  CONNECTED  LED  lights  when  a 
properly connected battery is detected. 
•  When the tester digital display is set to 
VOLTAGE, the CHARGED and CHARG-
ING LEDs won't light (it could be testing 
a battery or an alternator).
INITIAL PERCENT CALCULATION
When a battery % is calculated for the 
first time after connecting a battery, the 
digital display will show three dashes 
(“---”) for a period as long as several 
seconds while the tester analyzes the 
battery.
NOTES FOR TESTING BATTERY %
A recently charged battery could have a 
temporarily high voltage due to what is 
known as “surface charge”. The volt-
age of such a battery will gradually drop 
during the period immediately after 
the charging system is disengaged. 
Consequently, the tester could display 
inconsistent values for such a battery. 
For a more accurate reading, the surface