Schumacher SC-6500A 用户手册

下载
页码 32
11
This battery charger has a built-in alter-
nator tester that displays either an accu-
rate alternator voltage or an estimate of 
the alternator’s relative output compared 
to normal alternators. The Alternator % 
values displayed should be taken as 
general reference, not precise diagnosis. 
The alternator tester functions the same 
as the battery tester (see previous sec-
tion of this manual for details) with a few 
differences.
TESTING SEQUENCE
There are three basic steps required to use 
the SC-6500A as an alternator tester.
1.  Connect the charger battery clamps to 
the battery or charging system. Be sure 
to follow all of the precautions listed 
under “OPERATING INSTRUCTIONS”. 
2.  Connect the charger power cord to a 
120V AC 2-prong wall outlet. Again, be 
sure to follow all of the precautions listed 
under “OPERATING INSTRUCTIONS”.
3.  Start the vehicle and turn on the 
vehicle’s headlights. Read the voltage 
on the digital display or press the 
DIGITAL DISPLAY button to set the 
tester to ALTERNATOR % and read 
the alternator percent.
USING THE BUILT-IN ALTERNATOR TESTER
TESTER STATUS LEDs
When  the  SC-6500A  is  operating  as  an 
alternator  tester,  the  status  LEDs  light 
under the following conditions.
•  The CHARGED (green) LED will light 
if the output of the charging system is 
at the normally desired level.
•  The CHARGING (yellow) LED does 
not light in the alternator test mode.
•  The CONNECTED LED lights if the 
tester detects a connection.
•  When the tester digital display is set 
to VOLTAGE, the CHARGED and 
CHARGING LEDs won't light (it could 
be testing a battery or an alternator).
ALTERNATOR TESTING NOTES
•  The alternator percent display can 
range from 0 to 199.
•  The DIGITAL DISPLAY cannot be set 
to ALTERNATOR % during charging.
charge should be removed by temporar-
ily creating a load on the battery, such as 
by turning on lights or other accessories.
The battery % ranges from 0 to 100.
The battery tester is only designed to 
test batteries. Testing a device with a 
rapidly changing voltage could yield 
unexpected or inaccurate results.