To set battery type to one of the following two selections, press 
the BATTERY TYPE button. 
•  12 Volt: Battery typically used in cars, trucks and motorcycles. 
These batteries usually have vent caps and are often marked 
“low maintenance” or “maintenance-free.”
•  6 Volt: Battery typically used in antique and some specialized 
vehicles.
Automatic Shut Off: When the 2A, 4A or 6A charge rate is 
selected, the Battery Manager is set to perform an automatic 
charge. The charging process stops automatically after the battery 
is charged. 
Aborted Charge: If the charging process cannot be completed 
normally, charging is aborted. The Battery Manager’s output is 
shut off and the CHECK (red) LED blinks. In this state, the Bat-
tery Manager’s buttons are inoperative. To reset after an aborted 
charge, unplug the Battery Manager and plug it in again.
Charging Complete: The CHARGED (green) LED illuminates 
when charging is complete. The Battery Manager stops charging 
and switches automatically to Maintain Mode.