Mitsubishi Electronics MDS-R 用户手册

下载
页码 362
 
11. Inspection 
 
 
 
 
 
11 - 2
 
 WARNING
 
1.  Turn the main circuit power and control power both OFF before starting 
maintenance and inspection. It will take approx. 10 minutes for the main 
circuit's capacitor to discharge. After the CHARGE LAMP goes out, use a 
tester to confirm that the input and output voltages are zero. 
Failure to 
observe this could lead to electric shocks.
 
2.  Inspections must be carried out by a qualified technician. Failure to observe 
this could lead to electric shocks. Contact the Service Center for repairs and 
part replacements. 
 
 
CAUTION
 
1.  Never perform a megger test (measure the insulation resistance) of the servo 
drive unit. Failure to observe this could lead to faults. 
2.  The user must never disassemble or modify this product. 
 
 
11-1  Inspections 
 
Periodic inspection of the following items is recommended. 
 
<1> Are any of the screws on the terminal block loose? If loose, tighten them. 
<2> Is any abnormal noise heard from the servomotor bearings or brake section? 
<3> Are any of the cables damaged or cracked? If the cables move with the machine, periodically 
inspect the cables according to the working conditions. 
<4> Is the core of the load coupling shaft deviated? 
 
11-2  Service parts 
 
A guide to the part replacement cycle is shown below. Note that these will differ according to the working 
conditions or environmental conditions, so replace the parts if any abnormality is found. Contact 
Mitsubishi branch or your dealer for repairs or part replacements. 
 
Part name 
Standard replacement time 
Remarks 
Smoothing capacitor 
10 years 
Cooling fan 
10,000 to 30,000 hours 
(2 to 3 years) 
Servo drive unit 
Battery 10,000 
hours 
Bearings 
20,000 to 30,000 hours 
Detector 
20,000 to 30,000 hours 
Servomotor 
Oil seal, V-ring 
5,000 hours 
The standard replacement time 
is a reference. Even if the 
standard replacement time is 
not reached, the part must be 
replaced if any abnormality is 
found. 
 
<1> Power smoothing capacitor  :  The characteristics of the power smoothing capacitor will deteriorate 
due to the effect of ripple currents, etc. The capacitor life is greatly 
affected by the ambient temperature and working conditions. 
However, when used continuously in a normal air-conditioned 
environment, the service life will be ten years. 
<2> Relays 
:  Contact faults will occur due to contact wear caused by the switching 
current. The service life will be reached after 100,000 cumulative 
switches (switching life). 
<3> Servomotor bearings 
:  The motor bearings should be replaced after 20,000 to 30,000 hours 
of rated load operation at the rated speed. This will be affected by the 
operation state, but the bearings must be replaced when any 
abnormal noise or vibration is found in the inspections. 
<4> Motor oil seal, V-ring 
:  These parts should be replaced after 5,000 hours of operation at the 
rated speed. This will be affected by the operation state, but these 
parts must be replaced if oil leaks, etc., are found in the inspections.