15.0" 
±.02"
12.0" 
±.02"
Chapter 2 - Installation of Monitor 
This  monitor  is  intended  to  be  mounted  in  and  used  where  NEMA  4  and  NEMA  12  type 
enclosures  are  employed. 
Enclosures  made  of  heavier  gauge  metal  work  better  because  they  won’t 
deform  or  bend  as  ea
sily  when  the  monitor’s  sealing  gasket  is  compressed.  The  monitor meets  NEMA 
4/12 sealing specifications when properly installed in an approved NEMA enclosure constructed from 14-
gauge or heavier steel
.   The monitor uses “U”-shaped clips and a special gasket to achieve the proper 
seal. 
When selecting an enclosure remember to allow adequate space around the rear of the monitor 
for good air flow. Do not block air flow from below or above the monitor. If possible mount the monitor in a 
vertical  orientation.  The  monitor  is  designed  to  work  in  environments  up  to  50  degrees  Centigrade. 
Remember to account for heat dissipated from other equipment that may be inside the same enclosure. 
To install the monitor, make a cutout according to the diagram below in one of the walls of your 
NEMA enclosure.  Next hold the monitor in place while you install the mounting clips.    Tighten the clips 
to  the  point  were  the  back  of  the  monitor’s  front  bezel  just  begins  to  contact  the  front  of  the  NEMA 
enclosure. The use of an adjustable torque driver is recommended. The screws should be tightened to 8 
inch-pounds.  Tighten  the  clips  in  a  cross  pattern.  This  will  help  to  develop  an  even  pressure  on  the 
sealing  gasket.  DO  NOT  OVER  TIGHTEN  AS  DAMAGE  CAN  RESULT  IN  THE  MONITOR  CAUSING 
LOSS OF SEALING INTEGRITY.  
 
 
 
 
Cutout Pattern for M1500 / M1500T Monitor