Behringer EP2500 用户手册

下载
页码 14
EUROPOWER EP1500/EP2500
Applications
7
Power is supplied via an IEC connector. The matching cable 
[14] 
is provided with the unit.
SERIAL NUMBER of your EUROPOWER. 
[15] 
Here you can find a detailed overview of the individual MODE 
[16] 
SWITCHES functions ({9}).
Configuration switches (MODE SWITCHES)
2.3 
DIP-switches
Fig. 2.3: 
Clip limiter
2.3.1 
When the input signal connected to your amp is too high, you end 
up with a distorted output signal. To prevent this, both channels 
of your EUROPOWER feature a clip limiter that can be  engaged 
or disengaged selectively. The limiters automatically recognize 
distortion  and  lower  amplification  until  distortion  is  reduced  to 
a tolerable level. To preserve the dynamic characteristics of the 
signal when low distortion levels are occurring, the clip limiters 
function with moderate suppression. Use switches 1 (ch. 1) and 
10 (ch. 2) to activate the clip limiters.
When  using  broadband  loudspeaker  systems,  the  clip  limiter 
reduces high frequency distortions which occur when an amp-
lifier  is  overloaded. The  drivers  are  thus  protected  from  being 
damaged.
Input filter
2.3.2 
The LF (high-pass) filter removes frequencies below 30 and 50 Hz 
respectively. The reproduction of the signal’s bass portion is thus 
optimized, since ultra-low, distracting frequencies are eliminated, 
and more power is available for the reproduction of the wanted 
segment of the signal. Engaging and disengaging the filters is done 
by using the switches 3 (ch. 1) and 8 (ch. 2). Switches 2 (ch. 1) 
and 9 (ch. 2) determine the cut-off frequency. As long as the filter is 
disengaged, frequencies below 5 Hz are cut to prevent damage.
You should set up the filters so they best suit the frequency res-
ponse of your speakers, since some speakers (e.g. bass reflex 
speakers) are particularly sensitive to over-excursion below the 
listed frequency range.
The  50  Hz  filter  should  be  engaged  when  using  broadband 
speakers  because  the  filter  provides  a  moderate  amplification 
in the 100-Hz range, resulting in a fuller sound. The 30 Hz filter 
is  ideally  suited  for  subwoofer  operation  as  well  as  for  broad-
band cabinets. The “Off” setting should be used only for special 
applications (e.g. studio applications), in which recognizing and 
subsequently removing infra-sound is important.
2-channel mode (stereo)
2.3.3 
Both  channels  of  your  amp  function  independently  from  one 
another in this operating mode, and each has its own input sig-
nal. Two independent speakers are connected at the outputs. To 
activate this operating mode, please set the MODE SWITCHES 
4 and 5 to “STEREO”.
When running the unit in two-channel mode, the swit-
 
+
ches for mono-bridged mode must be disengaged (dip 
switches 6 and 7 in left position).
Parallel mode
2.3.4 
Running in parallel mode enables you to feed a signal via one of the 
inputs into both outputs. Each channel drives its own loudspeaker 
with independent amplification, filter and limit characteristics. To 
link the inputs, set the MODE SWITCHES 4 and 5 to “PARALLEL 
INPUTS”.
Mono-bridged mode switches must be disengaged when 
 
+
running in parallel mode. 
With inputs set to parallel, you can use the remaining input con-
nectors to feed the signal into additional amplifiers. This means 
that the channel 2 inputs function as outputs.
The parallel mode is well-suited for applications in which driving 
two speakers with the same signal but with separate amplification, 
filter and limiter settings is desired.
Mono-bridged mode
2.3.5 
This operating mode enables you to add up the respective vol-
tage of both channels and use it to drive a single loudspeaker. 
The voltage is therefore doubled, the peak power is quadrupled, 
and  program  power  is  roughly  three  times  as  high  as  that  of 
the individual channels. The input, output, gain, filter and limiter 
controls belonging to channel 1 are used when running in mono-
bridged mode. The controls belonging to channel 2 are not used. 
To prevent signal cancellation due to internal phase inversion, 
the GAIN control belonging to channel 2 must be turned to its 
left-most position.
Use this operating mode to route the power from both channels 
to a single 8-Ohm or 4-Ohm load. To do so, set up the switches 6 
and 7 to “BRIDGE MODE ON”. To use the binding posts as your 
output, you MUST use the two middle posts only. 
The mono-bridged mode puts added demands on ampli-
 
+
fier and speakers. Excessive distortion may occasionally 
completely mute the amp’s outputs as well as cause 
permanent damage to the speakers. Please assure that 
your speakers (minimal impedance 4 Ohms) as well as 
the cables used can handle the extra power generated 
in this mode.
Applications
3. 
Running EUROPOWER amplifiers in conjunction with 
 
+
8-Ohm speakers with a power rating of at least 2 x 260 
Watts (EP1500) and 2 x 450 Watts (EP2500) is recom-
mended to assure optimal operation. 
Differences between 2-channel, parallel  
3.1 
and mono-bridged operating modes 
2-channel mode is the most common operating mode of ampli-
fiers. Both channels operate fully independently from one another. 
There is always a separate input signal as well as a separate 
output signal.