EUROPOWER EP1500/EP2500
Applications
9
Examples:
Driving a single 8-Ohm loudspeaker.
 
=
Driving a single 4-Ohm loudspeaker.
 
=
Mono-bridged mode
Fig. 3.5: 
DIP switch positions for mono-bridged mode
Fig. 3.6: 
When the amp is overdriven for longer periods of time, 
 
+
the output signal may occasionally be muted for several 
seconds.  In  certain  situations,  excessive  overdriving 
may trigger off the automated fuse. To avoid overdriving 
the amp, please continually make sure that an approp-
riate volume level is applied. 
Caution
2-Ohm loads should never be applied when in mono-
 
+
bridged mode.
When connecting a balanced input signal, please make 
 
+
sure to exclusively use balanced cables for passing the 
signal further on. Otherwise, a single unbalanced cable 
can turn the entire signal unbalanced.
Safety precautions for  
mono-bridged operation 
Running your amp in mono-bridged mode can quickly 
 
+
result in excessive overdriving and premature shutting 
down of the unit itself. In the worst-case scenario, your 
loudspeakers may be damaged permanently. Therefore, 
you should always make sure that the speakers you use 
can indeed handle the power load fed into them. 
A voltage of up to 100 V RMS is present between the 
 
+
output  connectors  of  the  EP2500. Always  implement 
appropriate safety precautions when connecting your 
speakers to avoid the risk of electric shock. 
Bi-amping
3.2 
By using an active crossover, you can divide up the frequency 
range into several bands. For example, in doing so you can split 
a mono signal into upper-frequency and lower-frequency ranges. 
These two signals can then be hooked up to the inputs of your 
amp, so that channel 1 amplifies the lows and channel 2 amplifies 
the highs (2-channel operation). The outputs are  connected to 
a 2-way speaker, whereby the output signal 1 drives the woofer 
and output signal 2 runs the drivers. Of course, you can use two 
separate speakers instead of a single 2-way speaker.
A stereo signal can also be split up analogous to the example 
described above. However, to do that you need two 2-way spea-
kers or 4 separate speakers, two EUROPOWER amps and an 
active 2-way stereo crossover. The BEHRINGER SUPER-X PRO 
CX2310 is optimally suited for this ask and offers additionally a 
single mono-subwoofer output. By deploying a third EP1500 amp 
(preferably in mono-bridged mode) and a subwoofer, you have a 
perfect setup that adds a low-frequency system to the stereo bi-
amp application (see fig. 3.4). The amp’s input filters for the high/
mid-frequency ranges should in this case be engaged and set at 
50 Hz. To remove low, disturbing frequencies from the signal, the 
input filter for the subwoofer signal should be set at 30 Hz.
The BEHRINGER EUROLIVE SERIES loudspeakers are an out-
standing solution for expanding your P.A. system, because each 
frequency  range/application  has  a  speaker  type  that  optimally 
suits its characteristics.
Extreme clip limiter settings in bi-amp operating mode 
 
+