Maintenance and Diagnosis 
7.3  Troubleshooting Procedure 
7.3.1  Troubleshooting procedure 
This section describes the troubleshooting procedures for a disk drive failure at 
field maintenance level described in Subsection 7.1.3. 
In this section, troubleshooting is made to isolate the reported failure to the disk drive 
or a host system.  Usually, troubleshooting is necessary only when a cause of failure is 
uncertain or unknown.  When a cause of failure is clear (for example, abnormal sound 
in the DE or burnt parts on the PCA), a level of troubleshooting is low. 
7.3.2  Troubleshooting disk drive replaced in field 
It is recommended that the whole drive be replaced in maintenance of this level.  If 
replacing the drive corrects the fault, return the old drive to the factory for testing 
and repair.  If the new drive shows the same fault as the one that was removed, the 
failure is elsewhere in the system. 
System level troubleshooting, shown in Table 7.3, is performed at the user site to 
isolate the reported failure to the disk drive or system. 
7-12 
C141-E259