7.3  Troubleshooting Procedure 
Table 7.3  System level and field troubleshooting 
Check to be made 
Recommended work 
DC power voltage 
level 
Confirm that the DC power voltage is within 
±5% of the standard value.  
When measured at +5 V power pins P8 or P9 and GND pins P4-P6, P10, 
or P12 of the power supply connector, the +5 DVC must be 4.75 to 5.25 
VDC.
 
Refer to Sections 3.3 and 5.1.4.
 
DC power ripple 
noise 
Check that the maximum ripple at +5 VDC power is less than 100 mV 
peak to peak and 200 mV peak to peak respectively. 
SATA Interface 
Connection 
(Including a 
Connection of 
Power Segment)
 
Confirm that the SATA interface at the drive is properly connected with 
the host receptacle.
 
System cable 
Confirm that all cable connections throughout the system correctly 
connected. 
System diagnostic 
test 
To further isolate the failure, if it can be done, execute the system level 
diagnostic routine described in the host computer manual. 
Intermittent or 
indefinite error 
Check the AC voltage level at the power supply section and recheck the 
DC voltage level at the disk drive power supply connector. 
If the AC voltage level is abnormal, or if there is a lot of electrical noise, 
notify the user. 
If the DC voltage level is unstable, replace the power supply section. 
If possible, replace the disk drive.  If the fault remains, the disk drive is 
not the case.  For suggestions to isolate the failure further, refer to the 
hardware and software manuals provided with the system. 
 
C141-E259 
7-13