Fujitsu MHY2040BH 用户手册

下载
页码 322
 
5.2  Logical Interface 
C141-E262 
5-23 
(2) 
Features Field (exp)  
The Features Field provides specific feature to a command. For instance, it is used 
with SET FEATURES command to enable or disable caching. 
(3) 
Sector Count Field (exp) 
The Sector Count Field indicates the number of sectors of data to be transferred in 
a read or write operation between the host system and the device.  When the value 
in this field is X '00', the sector count is 256.  With the EXT system command, the 
sector count is 65536 when value of the Sector Count Field is X '00' and that of 
the Sector Count Field (exp) is X '00'. 
When this field indicates 0 at the completion of the command execution, this 
indicates that the command is completed successfully.  If the command is not 
completed successfully, this field indicates the number of sectors to be transferred 
to complete the request from the host system.  That is, this field indicates the 
number of remaining sectors that the data has not been transferred due to the 
error.  However, as of the last sector of PIO transfer, SC=1 indicates the normal 
completion. 
The contents of this field also have other definitions (Refer to 5.4) 
(4) 
Sector Number Field (exp) 
The contents of this field indicate the starting sector number for the subsequent 
command.  The sector number should be between X '01' and [the number of 
sectors per track defined by INITIALIZE DEVICE PARAMETERS command. 
Under the LBA mode, this field indicates LBA bits 7 to 0.  Under the LBA mode 
of the EXT system command, LBA bits 31 to 24 are set in the Sector Number 
Field, and LBA bits 7 to 0 are set in the Sector Number Field (exp). 
(5) 
Cylinder Low Field (exp) 
The contents of this field indicate low-order 8 bits of the starting cylinder address 
for any disk-access. 
At the end of a command, the contents of this field are updated to the current 
cylinder number. 
Under the LBA mode, this field indicates LBA bits 15 to 8.  Under the LBA mode 
of the EXT system command, LBA bits 39 to 32 are set in the Cylinder Low 
Field, and LBA bits 15 to 8 are set in the Cylinder Low Field (exp).