Interface 
 
5-24 
C141-E262 
(6) 
Cylinder High Field (exp) 
The contents of this field indicate high-order 8 bits of the disk-access start 
cylinder address. 
At the end of a command, the contents of this field are updated to the current 
cylinder number. The high-order 8 bits of the cylinder address are set to the 
Cylinder High Register. 
Under the LBA mode, this field indicates LBA bits 23 to 16.  Under the LBA 
mode of the EXT system command, LBA bits 47 to 40 are set in the Cylinder 
High Field, and LBA bits 23 to 16 are set in the Cylinder High Field (exp). 
(7) Device/Head 
Field 
The contents of this field indicate the device and the head number. 
When executing INITIALIZE DEVICE PARAMETERS command, the contents 
of this field defines "the number of heads minus 1" (a maximum head No.). 
 
Bit 7 
Bit 6 
Bit 5 
Bit 4 
Bit 3 
Bit 2 
Bit 1 
Bit 0 
X  HS3 HS2 HS1 HS0 
 
 
- Bit 7:  Unused 
- Bit 6:  L 
0 for CHS mode and 1 for LBA mode. 
- Bit 5:  Unused 
- Bit 4:  Unused 
- Bit 3:  HS3 
CHS mode head address 3 (2
3
).  bit 27 for LBA mode.  
Unused under the LBA mode of the EXT command. 
- Bit 2:  HS2 
CHS mode head address 2 (2
2
).  bit 26 for LBA mode.  
Unused under the LBA mode of the EXT command. 
- Bit 1:  HS1 
CHS mode head address 1 (2
1
).  bit 25 for LBA mode.  
Unused under the LBA mode of the EXT command. 
- Bit 0:  HS0 
CHS mode head address 0 (2
0
).  bit 24 for LBA mode.  
Unused under the LBA mode of the EXT command.