5.2  Logical Interface
 
C141-E218 
5-13 
(10)  Command register (X’1F7’)  
The Command register contains a command code being sent to the device.  After 
this register is written, the command execution starts immediately. 
Table 5.3 lists the executable commands and their command codes.  This table 
also lists the necessary parameters for each command which are written to certain 
registers before the Command register is written. 
 
5.2.3  Control block registers 
(1)  Alternate Status register (X’3F6’)  
The Alternate Status register contains the same information as the Status register 
of the command block register. 
The only difference from the Status register is that a read of this register does not 
imply Interrupt Acknowledge and INTRQ signal is not reset. 
 
Bit 7 
Bit 6 
Bit 5 
Bit 4 
Bit 3 
Bit 2 
Bit 1 
Bit 0 
BSY DRDY  DF  DSC  DRQ 