Cypress CY8C24123A 用户手册

下载
页码 56
CY8C24123A
CY8C24223A, CY8C24423A
Document Number: 38-12028  Rev. *I
Page 28 of 56
DC Analog Reference Specifications
The following tables list the guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V
and -40°C 
≤ T
A
 
≤ 85°C, 3.0V to 3.6V and -40°C ≤ T
A
 
≤ 85°C, or 2.4V to 3.0V and -40°C ≤ T
A
 
≤ 85°C, respectively. Typical parameters
apply to 5V, 3.3V, and 2.7V at 25°C and are for design guidance only.
The guaranteed specifications are measured through the Analog Continuous Time PSoC blocks. The power levels for AGND refer to
the power of the Analog Continuous Time PSoC block. The power levels for RefHi and RefLo refer to the Analog Reference Control
register. The limits stated for AGND include the offset error of the AGND buffer local to the Analog Continuous Time PSoC block.
Reference control power is high.
Note Avoid using P2[4] for digital signaling when using an analog resource that depends on the Analog Reference. Some coupling
of the digital signal may appear on the AGND.
Table 25.  5V DC Analog Reference Specifications
Symbol
Description
Min
Typ
Max
Units
BG
Bandgap Voltage Reference
1.28
1.30
1.33
V
AGND = Vdd/2
Vdd/2 - 0.04
Vdd/2 - 0.01
Vdd/2 + 0.007
V
AGND = 2 x BandGap
2 x BG - 0.048
2 x BG - 0.030
2 x BG + 0.024
V
AGND = P2[4] (P2[4] = Vdd/2)
P2[4] - 0.011
P2[4]
P2[4] + 0.011
V
AGND = BandGap
BG - 0.009
BG + 0.008
BG + 0.016
V
AGND = 1.6 x BandGap
1.6 x BG - 0.022
1.6 x BG - 0.010
1.6 x BG + 0.018
V
AGND Block to Block Variation 
(AGND = Vdd/2)
-0.034
0.000
0.034
V
RefHi = Vdd/2 + BandGap
Vdd/2 + BG - 0.10
Vdd/2 + BG
Vdd/2 + BG + 0.10
V
RefHi = 3 x BandGap
3 x BG - 0.06
3 x BG
3 x BG + 0.06
V
RefHi = 2 x BandGap + P2[6] (P2[6] = 1.3V) 2 x BG + P2[6] - 0.113 2 x BG + P2[6] - 0.018 2 x BG + P2[6] + 0.077
V
RefHi = P2[4] + BandGap (P2[4] = Vdd/2)
P2[4] + BG - 0.130
P2[4] + BG - 0.016
P2[4] + BG + 0.098
V
RefHi = P2[4] + P2[6] (P2[4] = Vdd/2 
P2[6] = 1.3V)
P2[4] + P2[6] - 0.133 P2[4] + P2[6] - 0.016
P2[4] + P2[6]+ 0.100
V
RefHi = 3.2 x BandGap
3.2 x BG - 0.112
3.2 x BG
3.2 x BG + 0.076
V
RefLo = Vdd/2 – BandGap
Vdd/2 - BG - 0.04
Vdd/2 - BG 
0.024
Vdd/2 - BG + 0.04
V
RefLo = BandGap
BG - 0.06
BG
BG + 0.06
V
RefLo = 2 x BandGap - P2[6] (P2[6] = 1.3V) 2 x BG - P2[6] - 0.084 2 x BG - P2[6] + 0.025 2 x BG - P2[6] + 0.134
V
RefLo = P2[4] – BandGap (P2[4] = Vdd/2)
P2[4] - BG - 0.056
P2[4] - BG + 0.026
P2[4] - BG + 0.107
V
RefLo = P2[4]-P2[6] (P2[4] = Vdd/2, 
P2[6] = 1.3V)
P2[4] - P2[6] - 0.057
P2[4] - P2[6] + 0.026
P2[4] - P2[6] + 0.110
V
Table 26.  3.3V DC Analog Reference Specifications 
Symbol
Description
Min
Typ
Max
Units
BG
Bandgap Voltage Reference
1.28
1.30
1.33
V
AGND = Vdd/2
Vdd/2 - 0.03
Vdd/2 - 0.01
Vdd/2 + 0.005
V
AGND = 2 x BandGap
Not Allowed
AGND = P2[4] (P2[4] = Vdd/2)
P2[4] - 0.008
P2[4] + 0.001
P2[4] + 0.009
V
AGND = BandGap
BG - 0.009
BG + 0.005
BG + 0.015
V
AGND = 1.6 x BandGap
1.6 x BG - 0.027
1.6 x BG - 0.010
1.6 x BG + 0.018
V
AGND Column to Column Variation 
(AGND = Vdd/2)
-0.034
0.000
0.034
mV
RefHi = Vdd/2 + BandGap
Not Allowed
RefHi = 3 x BandGap
Not Allowed
RefHi = 2 x BandGap + P2[6] (P2[6] = 0.5V)
Not Allowed
RefHi = P2[4] + BandGap (P2[4] = Vdd/2)
Not Allowed