Sun Ultra 60 Service Manual • August 2001
3.1
POST Overview
POST is useful in determining if a portion of the system unit has failed and should
be replaced. POST detects approximately 95 percent of system unit faults and is
located in the system board OpenBoot
PROM (OBP). The setting of two NVRAM
variables, the
diag-switch?
and the
diag-level
flag, determine if POST is
executed.
lists the
diag-switch?
and
diag-level
flag settings for
disabling POST (off), enabling POST maximum (max), or enabling POST minimum
(min).
3.2
Pre-POST Preparation
Pre-POST preparation includes:
Setting up a tip connection to another workstation or terminal to view POST
progress and error messages. See Section 3.2.1, “Setting Up a Tip Connection” on
page 3-3.
Verifying baud rates between a workstation and a monitor or a workstation and a
terminal. See Section 3.2.2, “Verifying the Baud Rate” on page 3-4.
If a terminal or a monitor is not connected to serial port A (default port) of a
workstation or server to be tested, the keyboard LEDs are used to determine error
conditions. See Section 3.7, “System and Keyboard LEDs” on page 3-22
TABLE 3-1
Diag-Level Switch Settings
Diag-Level Setting
POST
Initialization
Serial Port A
I/O
Serial Port A
Error Output
Diag-Switch?
Setting
Off
No
N/A
N/A
N/A
Max
Yes (power-on)
Enabled
Enabled
True
Min
Yes (power-on)
Disabled
Enabled
True