Lucent Technologies R5SI 用户手册
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-320
CO-DS1 (DS1 CO Trunk)
10
Port Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1
Interface circuit pack to assure that the trunk’s translation is correct. Translation
updates include the following data: trunk type (in/out), dial type, timing
parameters, and signaling bits enabled. The port audit operation verifies the
consistency of the current state of trunk kept in the DS1 Interface circuit pack
and in the switch software.
Interface circuit pack to assure that the trunk’s translation is correct. Translation
updates include the following data: trunk type (in/out), dial type, timing
parameters, and signaling bits enabled. The port audit operation verifies the
consistency of the current state of trunk kept in the DS1 Interface circuit pack
and in the switch software.
Table 10-90.
TEST #36 Port Audit and Update Test
Error
Code
Test
Result
Description/ Recommendation
ABORT
Internal System Error.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1000
ABORT
The test was aborted because system resources
required to run this test were not available. The port may
be busy with a valid call. Issue the
required to run this test were not available. The port may
be busy with a valid call. Issue the
display port
PCSSpp
command to determine the trunk
group/member number of the port. Use the
status trunk
command to determine the service state of the port. If
the service state indicates that the port is in use, then
the port is unavailable for certain tests. You must wait
until the port is idle before retesting.
the service state indicates that the port is in use, then
the port is unavailable for certain tests. You must wait
until the port is idle before retesting.
1. If the port status is active but the port is not in use
(no calls), check the error log for error type 1025
(see the error log table for a descriptionof this error
and required actions). The port may be locked up.
(see the error log table for a descriptionof this error
and required actions). The port may be locked up.
2. If the port status is idle, retry the command at
1-minute intervals for a maximum of 5 times.
3. If the test continues to abort, escalate the problem.
2000
ABORT
Response to the test request was not received within the
allowable time period.
allowable time period.
2100
ABORT
Could not allocate the necessary system resources to
run this test.
run this test.
FAIL
Test failed due to internal system error.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If test continues to fail, escalate the problem.
Continued on next page