DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-508
DIOD-DS1 (DS1 DIOD Trunk) 
10
DS1 CO Dial Tone Seizure Test (#314)
DS1 CO Dial Tone Seizure Test checks the trunk’s signaling capability provided 
by the DS1 Interface circuit pack. The maintenance software initiates the test by 
sending a ‘‘seizure’’ message to the DS1 Interface circuit pack and expects an 
‘‘active’’ reply from the DS1 interface circuit pack. If the ‘‘active’’ message is 
received, then the test passes. If no message is received and the timer expires, 
the test is aborted. If the DS1 Interface circuit pack sends a ‘‘reorder’’ message 
back to maintenance software, then the test fails.
Table 10-137.
TEST #36 Port Audit and Update Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
Internal System Error
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to abort, escalate the problem.
2000
ABORT
Response to the test request was not received within the 
allowable time period.
2100
ABORT
Could not allocate the necessary system resources to 
run this test.
FAIL
Test failed due to internal system error.
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If test continues to fail, escalate the problem.
PASS
Trunk translation has been updated successfully. The 
current trunk states kept in the DS1 Interface circuit 
pack and switch software are consistent. If the trunk is 
busied out, the test will not run but will return PASS. To 
verify that the trunk is in-service:
1. Enter the 
status trunk
 command to verify that the 
trunk is in-service. If the trunk is in-service, no further 
action is necessary. If the trunk is out-of-service, 
continue to step 2.
2. Enter the 
release trunk
 command to put the trunk 
back into in-service.
3. Retry the test command.
Continued on next page