Maintenance Object Repair Procedures
Page 10-614
DUPINT (Duplication Interface Circuit Pack)
10
Duplication Interface Circuit Pack Sanity Circuit
Test (#273)
Test (#273)
This test is destructive.
This test checks the sanity hardware of a Duplication Interface circuit pack. The
Duplication Interface circuit pack processor is instructed to allow the on-board
circuit pack sanity timer to expire, which should cause the circuit pack to reset
itself. The software then allows the Duplication Interface circuit pack 15 seconds
to reset. After this time, the Duplication Interface circuit pack is queried for the
results of its background tests (see Test #271). If the Duplication Interface circuit
Duplication Interface circuit pack processor is instructed to allow the on-board
circuit pack sanity timer to expire, which should cause the circuit pack to reset
itself. The software then allows the Duplication Interface circuit pack 15 seconds
to reset. After this time, the Duplication Interface circuit pack is queried for the
results of its background tests (see Test #271). If the Duplication Interface circuit
Table 10-172.
TEST #272 Duplication Interface Circuit Pack
Invalid Message Query Test
Error
Code
Code
Test
Result
Description/Recommendation
1000
ABORT
System resources required to run this test are not available.
2000
ABORT
Response to the test request was not received within the allowable time
period.
period.
2033
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL
The Duplication Interface circuit pack is receiving an abnormal number of
corrupted messages.
corrupted messages.
1. First investigate other Duplication Interface circuit pack tests that are
not passing.
2. If this is the only test that fails, investigate and resolve all alarms
against PR-MAINT (Maintenance/Tape Processor).
3. Rerun the test. If the test still fails, follow the procedures for replacing
Common Control circuit packs and replace the Duplication Interface
circuit pack.
circuit pack.
4. Rerun the test.
NO
BOARD
BOARD
The Duplication Interface circuit pack has failed to handshake with either
the active Maintenance/Tape Processor (in the case of Duplication
Interface circuit pack A) or the Duplication Interface circuit pack A (in the
case of Duplication Interface circuit pack B).
the active Maintenance/Tape Processor (in the case of Duplication
Interface circuit pack A) or the Duplication Interface circuit pack A (in the
case of Duplication Interface circuit pack B).
1. Refer to NO BOARD description for the Duplication Interface Circuit
Pack Status Query Test (#315).
PASS
The Duplication Interface circuit pack has not received any bad messages
from either Maintenance/Tape Processor or the other Duplication Interface
circuit pack. All serial links are operating fine.
from either Maintenance/Tape Processor or the other Duplication Interface
circuit pack. All serial links are operating fine.
Continued on next page