Maintenance Object Repair Procedures 
Page 10-614
DUPINT (Duplication Interface Circuit Pack) 
10
Duplication Interface Circuit Pack Sanity Circuit 
Test (#273)
This test is destructive.
This test checks the sanity hardware of a Duplication Interface circuit pack. The 
Duplication Interface circuit pack processor is instructed to allow the on-board 
circuit pack sanity timer to expire, which should cause the circuit pack to reset 
itself. The software then allows the Duplication Interface circuit pack 15 seconds 
to reset. After this time, the Duplication Interface circuit pack is queried for the 
results of its background tests (see Test #271). If the Duplication Interface circuit 
Table 10-172.
TEST #272 Duplication Interface Circuit Pack 
Invalid Message Query Test 
Error 
Code
Test 
Result
Description/Recommendation
1000
ABORT
System resources required to run this test are not available.
2000
ABORT
Response to the test request was not received within the allowable time 
period.
2033
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL
The Duplication Interface circuit pack is receiving an abnormal number of 
corrupted messages.
1. First investigate other Duplication Interface circuit pack tests that are 
not passing.
2. If this is the only test that fails, investigate and resolve all alarms 
against PR-MAINT (Maintenance/Tape Processor).
3. Rerun the test. If the test still fails, follow the procedures for replacing 
Common Control circuit packs and replace the Duplication Interface 
circuit pack.
4. Rerun the test.
NO 
BOARD
The Duplication Interface circuit pack has failed to handshake with either 
the active Maintenance/Tape Processor (in the case of Duplication 
Interface circuit pack A) or the Duplication Interface circuit pack A (in the 
case of Duplication Interface circuit pack B).
1. Refer to NO BOARD description for the Duplication Interface Circuit 
Pack Status Query Test (#315).
PASS
The Duplication Interface circuit pack has not received any bad messages 
from either Maintenance/Tape Processor or the other Duplication Interface 
circuit pack. All serial links are operating fine.
Continued on next page