DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-943
MMI-PT
10
Error Log Entries and Test to Clear Values
Notes:
a. The customer endpoint connected on a conference sent too many
messages to the VSP-MCU in a specified amount of time. Check the
“status conference” forms to correlate which customer had the problem.
This is a customer endpoint problem and not a VSP-MCU problem.
“status conference” forms to correlate which customer had the problem.
This is a customer endpoint problem and not a VSP-MCU problem.
b. This port has been busied out by the
busyout port PCSSpp
command.
c. Indicates that the circuit pack has been removed or has been insane for
more than 11 minutes. To clear the error, replace or reseat the circuit
pack.
pack.
d. This error occurs if the MMI circuit pack detects a DSP Error. Maintenance
software will reset the DSP when this error is received. This error is logged
for all 8 resources connected to this particular DSP. If this DSP continues
to fail sanity, a Minor alarm is raised. Replace the circuit pack.
for all 8 resources connected to this particular DSP. If this DSP continues
to fail sanity, a Minor alarm is raised. Replace the circuit pack.
e. This error occurs when the Resource Looparound Test (#1111) fails. Run
the Long Test Sequence and note the results of Test #1111.
f. This error occurs if either the MMI or Voice Conditioner (VC) circuit packs
reports a loss of framing on the service channel between these two circuit
packs. When a customer endpoint establishes a call to the VSP-MCU, a
channel is established between the MMI resource and the VC port. If this
channel is detected to go down by either circuit pack, an uplink message
is sent. This error is then forwarded to maintenance for both circuit packs.
packs. When a customer endpoint establishes a call to the VSP-MCU, a
channel is established between the MMI resource and the VC port. If this
channel is detected to go down by either circuit pack, an uplink message
is sent. This error is then forwarded to maintenance for both circuit packs.
1.
Run the short test sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
appropriate test description and follow the recommended procedures.
Table 10-270.
MMI-PT Error Log Entries
Error
Type
Type
Aux
Data
Associated Test
Alarm
Level
On/ Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1 (a)
Any
Uplink error from pack
18 (b)
0
Busyout port PCSSpp
WNG
OFF
release port PCSSpp
130 (c)
Any
Software generated
WNG
ON
257 (d)
Any
None
MAJ/
MIN
MIN
ON
513 (e)
Any
Resource Loopback
Test (#1111)
Test (#1111)
MIN
ON
test port PCSSpp sh r 3
1025 (f)
Any
Uplink error from pack
3841 -
3844 (g)
3844 (g)
Any
Uplink error from pack