Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-944
MMI-PT 
10
Run the Long Test Sequence for this MMI resource, and if any of the tests 
fail, follow the repair procedures for that test. If all tests pass, the cause of 
the problem might be with the VC pack. See the “VC-DSPPT” repair 
procedures.
g. These errors are not related to VSP-MCU. They could be caused by 
network problems or from the customer endpoints. They are presented 
here for logging purposes only:
System Technician-Demanded Tests: 
Descriptions and Error Codes
Resource Looparound Test (#1111)
This test is destructive.
This test checks the connectivity of the resource within MMI circuit pack and out 
to the TDM bus. The object is to test the circuitry that an H.221 bit stream comes 
in contact with when that stream is demultiplexed, pre-processed, written to the 
TDM bus and then reread (looped in the TSI), post-processed, multiplexed, and 
then written back to the TDM bus for verification. The video, audio, and data 
components of the bit stream are tested separately. If any one of these tests fails, 
then the resource is taken out of service.
1.
D = Destructive; ND = Nondestructive
Code
Description
3841
CRC4 Error (Frame checksum error)
3842
Correctable BAS (Control msg single or double bit error, but 
correctable)
3843
Uncorrectable BAS (Control msg bit error -three or more bit, 
uncorrectable)
3844
Protocol Error (H.221 Protocol error from endpoint detected)
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Resource Looparound Test (#1111)
X
X
D