DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1100
PKT-CTRL (Packet Control Circuit Pack) 
10
Packet Control Loop Around Test (#585)
This test checks whether the Packet Control circuit pack can send and receive 
data correctly. The test performs the following major functions:
1. Establishes an LAPD link from the Packet Control circuit pack to itself. 
(See 
.)
2. Transmits and receives test data over the testing link.
Figure 10-80.
Test Configuration
Packet
Control
Bus
Packet