Maintenance Object Repair Procedures 
Page 10-1098
PKT-CTRL (Packet Control Circuit Pack) 
10
Packet Control Parity Circuitry Test (#584)
This test checks the error detection capability of the Packet Control circuit pack’s 
circuitry by verifying that it correctly identifies frames on the Packet Bus with 
parity errors.
NOTE:
This test aborts in a High or Critical Reliability system, or in a system with an 
alarmed PPN Packet Bus.
FAIL
Software was unable to read and clear the Packet Control circuit pack 
error counters.
1. Retry the command.
2. If the same error code is observed, and the Packet Control circuit pack 
is on the active SPE and is not currently busied-out, issue the 
busyout 
packet-control C
 command. Issue the 
reset packet-control C
 
command. If the reset command fails, follow the recommended repair 
procedures for Test #586. If the reset command passes, issue the 
release packet-control C
 command (if the Packet Control circuit pack 
is on the active SPE), and then reissue the original command.
PASS
The Packet Control circuit pack succeeded in servicing the read and clear 
error counter requests.
Table 10-324.
TEST #584 Packet Control Parity Circuitry Test 
Error 
Code
Test 
Result
Description/ Recommendation
1024
ABORT
The Packet Control circuit pack’s parity circuitry is currently being used by 
another maintenance test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1139
ABORT
The PPN Packet Bus is alarmed.
1. Try to retire the alarm associated with the PKT-BUS (Packet Bus). 
Refer to the Alarm log via the 
display alarm
 command.
2. Retry the command when the alarm associated with the Packet Bus 
circuit pack is retired.