DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1170
PR-MEM (TN790 RISC Memory) 
10
Memory Parity Error Detection Test (#87)
This test is a nondestructive test. The test is run on a few reserved locations in 
memory. A failure of this test indicates a failure on the Processor circuit pack.
This test determines if the parity circuitry is working. Accordingly, the test 
determines if parity errors can be detected. The parity circuitry is used to detect 
DRAM memory failures.
Table 10-353.
TEST #86 Text Checksum Test
 
Error Code
Test 
Result
Description/ Recommendation
100
ABORT
The test did not complete within the allowable time period.
1. Retry the command.
1029 2014 
2015 2016 
2017 2018 
2020 2022 
2024 2025 
2051
ABORT
Refer to STBY-SPE Maintenance documentation for a description of 
these error codes.
2500
ABORT
Internal system error
1. Retry the command.
1 - 7
FAIL
The system may or may not continue to operate correctly. The system 
may fail later when some action requires access to the corrupted area 
of the Text.
1. The Flash ROM should be reprogrammed via the 
upgrade 
software
 command. The memory card should contain the same 
vintage software that is currently in the system. Refer to the 
"Software Upgrade" section in this manual.
2. If the test continues to fail, replace the TN790 Processor circuit 
pack and repeat step 1.
PASS
The checksum is correct.
Continued on next page