Maintenance Commands and Trouble-Clearing Aids 
Page 8-15
busyout journal-printer 
8
Parameters
Help Messages
If the system technician presses 
HELP
 after entering "busyout journal-printer," the 
following object command word choices will be displayed:
 pms-log           wakeup-log
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
 ’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message will be displayed:
 Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the 
following message will be displayed:
 All maintenance resources busy; try again later
Error Message
 Link not administered not enabled
Output
For the following output example, assume that the command that was entered is 
"busyout journal-printer wakeup-log."
pms-log
This will busyout the link to the pms printer. In the output the port name 
for the pms link is 1.
wakeup-log
This will busyout the link to the wakeup logging facility. In the output the 
port name for this object is 0.
Port
The port address (cabinet-carrier-slot-circuit) of the maintenance 
object that is being busied out. In this case, the physical object 
port address will be a 0 for wakeup log and a 1 for the pms log.
Maintenance Name
The type of maintenance object that is being busied out.
Alt. Name
Not applicable.
Result
An indicator as to whether the object was successfully busied 
out.
Error Code
A numerical description of why the command failed.