DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1422
TDM-CLK (TDM Bus Clock) 
10
Standby Reference Health Check Test (#651)
This test evaluates the quality of the external synchronization timing source for a 
standby Tone-Clock circuit pack. All administered synchronization timing 
sources must be valid for this test to pass. If the tone-clock circuit pack and the 
synchronization timing sources are in different port networks, the EI circuit packs 
transport the timing sources to the tone-clock.
 
PASS
The proper (TN780) Tone-Clock circuit pack code is present for Stratum 3 
Clock synchronization.
Table 10-436.
TEST #651 Standby Reference Health Check Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
This test may already be running due to a tone-clock installation, scheduled 
maintenance, alarm activity, or a technician-demand test from another 
terminal. This abort can also occur due to an internal system error.
1. Try the command again at 1-minute intervals up to five times.
1184
ABORT
This test requires an external synchronization source to be administered 
(DS1 primary, DS1 primary and secondary, or Stratum 3 Clock).
1.  Administer the external synchronization source and retry the test.
2500
ABORT
Internal System Error 
1. Try the command again at 1-minute intervals up to 5 times.
Continued on next page
Table 10-435.
TEST #574 Board Type Check Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page