Maintenance Object Repair Procedures
Page 10-1424
TIE-BD (Tie Trunk Circuit Pack)
10
TIE-BD (Tie Trunk Circuit Pack)
Refer to XXX-BD (Common Port Circuit Pack) Maintenance documentation for
circuit pack level errors. See also TIE-TRK (Tie Trunk).
circuit pack level errors. See also TIE-TRK (Tie Trunk).
1.
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier
designation (for example, A, B, C, D, or E); and SS is the address of the slot in the carrier
where the circuit pack is located (for example, 01, 02, ..., etc.).
designation (for example, A, B, C, D, or E); and SS is the address of the slot in the carrier
where the circuit pack is located (for example, 01, 02, ..., etc.).
MO Name As It
Appears in
Alarm Log
Alarm
Level
Initial System
Technician
Command to Run
1
Full Name of MO
TIE-BD
MIN
test board PCSS sh
Tie Trunk Circuit Pack
TIE-BD
WRN
test board PCSS sh
Tie Trunk Circuit Pack