Maintenance Object Repair Procedures 
Page 10-1545
UDS1-BD (UDS1 Interface Circuit Pack) 
10
Control Channel Loop Around Test (#52)
This test queries the circuit pack for its circuit pack code and vintage and verifies 
its records.
0
NO 
BOARD
The test could not relate the internal ID to the port (no 
board). This could be due to incorrect translations, no 
board is inserted, an incorrect board is inserted, or an 
insane board is inserted.
1. Ensure that the board translations are correct. 
Execute the 
add ds1 PCSS
 command to administer 
the UDS1 interface if it is not already administered.
2. If the board was already administered correctly, 
check the error log to determine whether the board 
is hyperactive. If this is the case, the board is shut 
down. Reseating the board will re-initialize the 
board.
3. If the board was found to be correctly inserted in 
step 1, then issue the 
busyout board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the linkage between the internal 
ID and the port.
Table 10-456.
TEST #50 NPE Connection Audit Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page