DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-56
change synchronization 
8
Description
A hierarchy of sources exists within each system that are used for timing 
synchronization. For stratum 3 synchronization, this hierarchy is reflected by the 
DS1 inputs to the external stratum 3 clock. For stratum 4 synchronization, this 
hierarchy is reflected in the primary and secondary fields. If all fields are blank, 
then the tone clock board within each PN provides timing for that PN.
Defaults
None.
Parameters
None.
Help Messages
If the user presses 
HELP
 after entering "change synchronization" the following 
message is displayed:
 
Entry is not required
Error Messages
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
 ’login id’:’command’ has a command conflict.