DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-57
change synchronization 
8
Output/INPUT 
Stratum:
This field specifies the synchronization stratum that will be used. The 
only entries that are acceptable are "3" and "4." If "4" is entered in this 
field, the message
Primary:
This field designates the first choice system synchronization source. A 
blank entry means no synchronization. This field is valid only if stratum 
4 synchronization is specified.
— FIELD 
HELP
:
 Enter 5 character board number;
 cabinet(1-3):carrier(A-E):slot(0-21)
— FIELD ERROR(S):
— "entry" Board location invalid
— "entry" Circuit Pack must be a DS1 or a UDS1 board
— "entry" Circuit pack must be installed first
— Cannot administer synchronization sources on a port network 
remoted via DS1C
Secondary:
This field designates the second choice system synchronization 
source. A blank entry means no synchronization. This field is valid only 
if stratum 4 synchronization is specified.
— FIELD 
HELP
:
 Enter 5 character board number; cabinet(1-3):carrier(A-E):
  slot(0-21)
— FIELD ERROR(S):
— "entry" Board location invalid
— "entry" Circuit Pack must be a DS1 or a UDS1 board
— "entry" Circuit pack must be installed first
— Secondary source requires primary synchronization source
— Duplicate entry
— Synchronization sources must be in same port network
Location:
The circuit pack location (port network, carrier and board slot) of all 
administered DS1 circuit packs are listed here.